Settings Pages
28
Modero S Series Touch Panels - Configuration & Programming Manual
G4 WebControl
An on-board VNC (Virtual Network Computing) server allows any remote PC running a VNC client to connect to the panel. Once
connected, the client can view and control the panel remotely. The options on the G4 WebControl page (FIG. 40) allow you to
enable or disable G4 WebControl functionality.
NOTE: The Modero S Series touch panels accelerate graphics rendering through hardware, not software. When accessing the panel
via VNC, a separate software graphics engine is used, which may slow down graphics and panel responsiveness. In addition to
slowing down graphics and panel responsiveness, any video and animated transitions will not be visible over VNC.
Function Show Example
When the Function Show feature is displayed, the Channel Port and Code will appear in yellow, the Address Port and Code in blue,
and the Level Port and Code in purple.
FIG. 40
G4 WebControl page
G4 WebControl Page
Back: Click the left-facing arrow to return to the previous page.
Connection Status: A green bar signifies that the panel has an active connection to the Master.
Close: Click the “X” button to shut the Settings page and return to the main display.
G4 WebControl: The G4 Web Control button toggles between the two G4 activation settings:
Off - deactivates G4 Web Control on the panel.
On - activates G4 Web Control on the panel.
Timeout: Sets the length of time (in minutes) that the panel can remain idle, detecting no cursor movements, before the
G4 Web Control session is terminated.
Minimum value = Off (panel never times out)
Maximum value = 4 h (panel times out after 4 hours)
Name: Use this field to enter a unique alpha-numeric string to be used as the panel’s display name. If the Synchronize
Device Names option (page 29) is enabled, this field will be greyed out.
Password: Use this field to enter the G4 Authentication session password required for VNC access to the panel.
Port: Use this field to enter the number of the port used by the VNC Web Server. Default = 5900.
Maximum Connections: Displays the maximum number of users that can be simultaneously connected to this panel via VNC. Press this
field to increase the number allowed to connect to this panel. Default = 1.
Current Connections: Displays the number of users currently connected to this panel via VNC.
FIG. 41 Function Show

Table of Contents

Other manuals for AMX MST-431

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX MST-431 and is the answer not in the manual?

AMX MST-431 Specifications

General IconGeneral
BrandAMX
ModelMST-431
CategoryTouch Panel
LanguageEnglish

Related product manuals