Configuring Communication
69
10" Modero Touch Panels
Master Connection section - Virtual Master communication over Ethernet
Before beginning:
1. Verify the panel has been configured to communicate either through an Ethernet cable (connected from
either the panel to a valid Ethernet Hub) or wireless to the Wireless Access Point.
2. Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx
Studio 2 > NetLinx Studio 2).
3. Select Settings > Master Communication Settings, from the Main menu to open the Master
Communication Settings dialog (FIG. 71).
4. Click the Communications Settings button to open the Communications Settings dialog.
5. Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are
working as a NetLinx Master.
6. Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate you
are wanting to configure the PC to communicate with a panel. Everything else such as the Authentication
is greyed-out because you are not going through the Master’s UI.
7. Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx
Master Settings dialog (FIG. 71).
8. From within this dialog enter the System number (default is 1) and note the IP Address of the target PC
being used as the Virtual Master. This IP Address can also be obtained by following these procedures:
On your PC, click Start > Run to open the Run dialog.
Enter cmd into the Open field and click OK to open the command DOS prompt.
From the C:\> command line, enter ipconfig to display the IP Address of the PC. This information
is entered into the Master IP/URL field on the panel.
9. Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio
application.
When configuring your panel to communicate with a Virtual Master (on your PC) via
Ethernet, the Master IP/URL field must be configured to match the IP Address of the
PC and make sure to use the Virtual System value assigned to the Virtual Master
within NetLinx Studio.
FIG. 71 Assigning Communication Settings and TCP/IP Settings for a Virtual Master
Enter this IP
into the
Master IP/URL
field on the
System Settings
page
IP Addresses of computer
(also obtained by using the
Start > Run > cmd command)

Table of Contents

Other manuals for AMX NXT-CV10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX NXT-CV10 and is the answer not in the manual?

AMX NXT-CV10 Specifications

General IconGeneral
Dimensions (WxDxH)283 x 84 x 202 mm
Ethernet LAN (RJ-45) ports1
Pixel pitch0.28 x 0.28 mm
Aspect ratio16:9
Screen shapeFlat
Display diagonal10 \
Display brightness350 cd/m²
Display resolution800 x 480 pixels
Contrast ratio (typical)350:1
USB Type-A downstream ports quantity2
CertificationFCC 15 B, CE, EN60950
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 85 %
Operating relative humidity (H-H)20 - 85 %
NVIDIA G-SYNCNo
Weight and Dimensions IconWeight and Dimensions
Weight (without stand)1200 g

Related product manuals