Frequency (Hz) Voltage (V) 30kW F21 (A) 37kW F21 (A) 45kW F21 (A)
60 230 67,9 77 96,3
60 460 33,9 39,8 48,5
60 575 27,4 31,9 38,5
Settings for fan motor overload protection (Q15)
Frequency (Hz) Voltage (V) 30kW Q15 (A) 37kW Q15 (A) 45kW Q15 (A)
IEC
50 230 4,7 4,7 4,7
60 230 4,2 4,2 4,2
60 380 2,4 2,4 2,4
50 400 2,7 2,7 2,7
60 460 2,4 2,4 2,4
50 500 2,2 2,2 2,2
UL/cUL
60 230 4,2 4,2 4,2
60 460 2,4 2,4 2,4
60 575 1,9 1,9 1,9
10.4 Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.
10.5 Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute) bar 1
Air inlet pressure (absolute) psi 14.5
Air inlet temperature ˚C 20
Air inlet temperature ˚F 68
Relative humidity % 0
Working pressure See section Compressor data.
Limits
Maximum working pressure See section Compressor data.