00.41
•
Rectify any faults found.
•
Set idle speed using recirculating air screws
while maintaining synchronous running.
Idle speed: ...................................1000
+
150
min
-1
L Note:
Make sure that both throttle valves are closed.
e Caution:
The sealed stop screws on the throttles must not be
tampered with, or else the basic idle flow setting will
have to be reset by the manufacturer.
•
Carefully reduce play at the left throttle until the
bar display on the Syncrotester changes.
•
Turn the adjusting screw until the bar display re-
verts to its original height.
•
Tighten the locknut.
L Note:
The height of the bar display must not change when
the locknut is tightened.
•
Repeat this procedure at the right throttle
L Note:
If play is zero, the throttle butterflies may chatter.
•
Adjust throttle cable play at screws (1).
•
Push the protective rubber cap (2) back over the
adjusting screw.
Throttle cable play:.......... app. 0.5 mm (0.0197 in)
•
Adjust choke cable to zero play at screw (1).
•
Push the protective rubber cap (2) over the ad-
justing screw.
•
Check the setting by turning the handlebar be-
tween the full right and left lock positions. Engine
speed must not change during this check.
RT000070
1
2
RT000140
RS 11.055
2
1
RT000080