Error Message Cause Action
Memory ERROR An attempt was made to recall data
(list, matrix, extra variable, formula
variable, etc.) that does not exist.
Check to make sure that the name
of the data you are trying to recall
is correct.
Go ERROR
• A “Goto
n
” in the program being
executed does not have a
corresponding “Lbl
n
”.
The fi le name being called up by
the Prog command does not exist.
Either add a “Lbl
n
” for the “Goto
n
command, or delete the applicable
“Goto
n
command.
Check to make sure that the fi le
name that way input following the
Prog command is correct.
Ne ERROR The number of nested If (page
116), For (page 116), While (page
117) or Do statements (page 117),
or subroutines (page 117) in the
program being executed exceeds
10.
Too many nested functions or
parentheses in a calculation.
Edit the program so the number of
nested statements or subroutines
is 10 or fewer.
Divide the calculation into multiple
parts and calculate each part
separately.
Transmit ERROR,
Receive ERROR
LINK Mode data communication
was interrupted during send
(Transmit ERROR) or receive
(Receive ERROR).
Make sure that the cable is
connected correctly.
Check to make sure that the
receiving calculator is in the receive
standby mode.
Memory Full Operation or memory storage
operation exceeds remaining
memory capacity.
Keep the number of memories you
use within the currently specifi ed
number of memories.
Simplify the data you are trying to
store to keep it within the available
memory capacity.
Delete no longer needed data to
make room for the new data.
Already Exists During data communication, a
program or fi le name in the data
being sent already is used in
receiving unit memory.
To overwrite the fi le currently in
receiving unit memory with the
program or fi le being sent, press
1
(Yes).
Range ERROR In the TABLE or RECUR Mode:
The table range specifi cation is
wrong.
An attempt is being made to
create a table with more than 199
lines.
Check the range specifi cation and
make the required corrections.
No Variable There is no variable to be solved
for in the equation you input for a
SOLVE calculation.
Change the equation to one that
has a variable to be solved for.

Table of Contents

Other manuals for Casio fx-5800P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio fx-5800P and is the answer not in the manual?

Casio fx-5800P Specifications

General IconGeneral
TypeScientific
Form factorPocket
Product colorBlack
Battery typeAAA
Number of batteries supported1
Weight and Dimensions IconWeight and Dimensions
Weight150 g
Dimensions (WxDxH)81.5 x 163 x 15.1 mm

Related product manuals