Page #54 background imageLoading...
Page #54 background image
2-36
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
FRNTEND_CTRLR Messages
FRNTEND_CTRLR Messages
Note These messages apply only to the Catalyst 3750-X and 3750-E switches.
Error Message FRNTEND_CTRLR-1-MGR_TXQ_FULL: The front end controller Tx queue
reached watermark level
Explanation There are too many messages in the queue between the front-end controller and the
switch software.
Recommended Action Reset the switch. If the problem is not resolved, contact your Cisco technical
support representative because there might be a problem with the switch.
Error Message FRNTEND_CTRLR-2-SUB_INACTIVE: The front end controller [dec] is
inactive.
Explanation The front-end controller that controls the LEDs, the PoE features, and the fan-control
features is now inactive on the port controlled by the front-end controller. This does not affect the
traffic on the port. [dec] is the controller number.
Recommended Action Reset the switch. If the problem is not resolved, contact your Cisco technical
support representative because there might be a problem with the switch.
GBIC_SECURITY Messages
Note The Catalyst 3750-X, 3750-E, 3560-X, and 3560-E switches support SFP modules and do not support
GBIC modules. Although the error message text refers to GBIC interfaces and modules, the messages
from the switches actually refer to the SFP and 10-Gigabit Ethernet module interfaces and modules.
Error Message GBIC_SECURITY-4-EEPROM_CRC_ERR: EEPROM checksum error for GBIC in
[chars].
Explanation The GBIC in the specified port has invalid EEPROM data. [chars] is the port in which
the GBIC is inserted.
Recommended Action Remove the GBIC from the port.
Error Message GBIC_SECURITY-4-EEPROM_READ_ERR: Error in reading GBIC serial ID in
[chars].
Explanation An error occurred while the switch was reading the GBIC type from the EEPROM.
[chars] is the port in which the GBIC is inserted.
Recommended Action Remove the GBIC from the port.

Table of Contents

Other manuals for Cisco Catalyst 3750-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750-X and is the answer not in the manual?

Cisco Catalyst 3750-X Specifications

General IconGeneral
BrandCisco
ModelCatalyst 3750-X
CategorySwitch
LanguageEnglish

Related product manuals