EasyManuals Logo
Home>Cisco>Switch>Catalyst 3750-X

Cisco Catalyst 3750-X Message Guide

Cisco Catalyst 3750-X
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
2-44
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
IFMGR Messages
IFMGR Messages
Error Message IFMGR-3-IFINDEX_PERSIST_ENTRY_CORRUPT: [chars] seems to be corrupted.
Trying to read [dec] size
Explanation The ifIndex table is corrupted. [chars] is the path to the IfIndex file, and [dec] is the
number of bytes that was being read from the ifIndex table when the corruption was detected.
Recommended Action Delete the ifIndex table.
Error Message IFMGR-3-INVALID_PERSISTENT_DATA: Invalid persistent data
Explanation The interface manager attempted to write invalid persistent data.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information.
IGMP_QUERIER Messages
Error Message IGMP_QUERIER-4-NO_IP_ADDR_CFG: The IGMP querier cannot send out
General Query messages in VLAN [dec] because there is no IP address configured on
the system.
Explanation An IP address for the IGMP querier was not configured at either the global or per-VLAN
level. [dec] is the VLAN ID.
Recommended Action Configure a source IP address for the IGMP querier.
Error Message IGMP_QUERIER-4-PIM_ENABLED: The IGMP querier is operationally disabled
in VLAN [dec] because PIM has been enabled on the SVI.
Explanation Protocol-Independent Multicast (PIM) was detected on the switch virtual interface
(SVI). Do not enable the IGMP querier when PIM is enabled on the SVI. [dec] is the VLAN ID.
Recommended Action Ensure that PIM is disabled on the SVI.
Error Message IGMP_QUERIER-4-SNOOPING_DISABLED: The IGMP querier is operationally
disabled in VLAN [dec] because IGMP snooping has been disabled in this VLAN.
Explanation IGMP snooping is disabled on this VLAN. Do not enable the IGMP querier when IGMP
snooping is disabled. [dec] is the VLAN IDs.
Recommended Action Confirm that IGMP snooping is enabled both globally and on the VLAN.

Table of Contents

Other manuals for Cisco Catalyst 3750-X