Page #40 background imageLoading...
Page #40 background image
2-14
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Chapter 2 Installing the Server
NIC Modes and NIC Redundancy Settings
NIC Modes and NIC Redundancy Settings
NIC Modes
This server has the following NIC mode settings that you can choose from:
Shared LOM EXT (default)—This mode is the shared LOM extended mode that is the
factory-default setting. With this mode, the shared LOM and Cisco Card interfaces are both enabled.
In this mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If
the system determines that the Cisco card connection is not getting its IP address from a Cisco UCS
Manager system because the server is in standalone mode, further DHCP requests from the Cisco
card are disabled. If the system determines that the Cisco card connection is getting its IP address
from a Cisco UCS Manager system, the reply has parameters that automatically move the server to
UCSM mode.
Dedicated—The dedicated management port is used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
Shared LOM—The 1-Gb Ethernet ports are used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
Cisco Card—The ports on an installed Cisco UCS virtual interface card (VIC) are used to access
Cisco IMC. You must select a NIC redundancy and IP setting.
See also the required VIC Slot setting below.
VIC Slot—If you use the Cisco Card NIC mode, you select this setting to match where your VIC is
installed. The choices are Riser1, Riser2, or Flex-LOM (the mLOM slot).
If you select Riser1, slot 2 is the primary slot, but you can also use slot 1.
If you select Riser2, slot 5 is the primary slot, but you can also use slot 4.
If you select Flex-LOM, you must use an mLOM-style VIC in the mLOM slot.
NIC Redundancy
This server has the following NIC redundancy settings that you can choose from:
None—The Ethernet ports operate independently and do not fail over if there is a problem. This
setting can be used only with the Dedicated NIC mode.
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
Active-active—All Ethernet ports are utilized simultaneously. Shared LOM EXT mode can
have only this NIC redundancy setting. Shared LOM and Cisco Card modes can have both
Active-standby and Active-active settings.
The active/active setting uses Mode 5 or Balance-TLB (adaptive transmit load balancing). This
is channel bonding that does not require any special switch support. The outgoing traffic is
distributed according to the current load (computed relative to the speed) on each slave.
Incoming traffic is received by the current slave. If the receiving slave fails, another slave takes
over the MAC address of the failed receiving slave.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M4 and is the answer not in the manual?

Cisco UCS C240 M4 Specifications

General IconGeneral
Tcase78.9 °C
Bus typeQPI
SteppingM1
Scalability2S
Processor codeSR1YA
Processor cache25 MB
Processor cores10
Processor modelE5-2650V3
System bus rate9.6 GT/s
Processor seriesIntel Xeon E5-2600 v3
Processor socketLGA 2011-v3
Processor threads20
Processor codenameHaswell
Motherboard chipsetIntel C610
Processor frequency2.3 GHz
Processor cache typeSmart Cache
Processor lithography22 nm
Processor manufacturerIntel
Processor package size52.5 x 45 mm
Processor front side bus- MHz
Processor boost frequency3 GHz
Processor operating modes64-bit
ECC supported by processorYes
Embedded options availableNo
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX 2.0
Thermal Design Power (TDP)105 W
Compatible processor seriesIntel® Xeon®
Supported processor socketsLGA 2011-v3 (Socket R)
Number of processors installed2
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR4-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor1600, 1866, 2133 MHz
Memory bandwidth supported by processor (max)68 GB/s
Maximum internal memory supported by processor768 GB
HDD size- \
RAID levels0, 1, 5, 6, 10, 50, 60
Total storage capacity- GB
Maximum storage capacity- TB
Number of HDDs installed-
Memory slots24
Internal memory16 GB
Memory clock speed2133 MHz
Maximum internal memory384 GB
Maximum graphics card memory8 MB
Graphics cardG200e
Graphics card familyMatrox
Intel® Virtualization Technology (Intel® VT)VT-d, VT-x
LAN controllerIntel® I350
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeFast Ethernet, Gigabit Ethernet
Serial ports quantity0
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports4
Compatible operating systemsMicrosoft Windows Server 2012 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2008 R2 Red Hat Enterprise Linux Novell SUSE Linux Enterprise Server Oracle Linux Oracle Solaris Ubuntu Server CentOS
Chassis typeRack (2U)
Power supply input frequency50 - 60 Hz
Processor ARK ID81705
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Trusted Platform Module (TPM) version1.2
PCI Express slots version3.0
Weight and Dimensions IconWeight and Dimensions
Depth738 mm
Width448 mm
Height87 mm