No. Function division Function DECOS3b
5 Self-diagnosis and • Open-phase running ✓
automatic back-up • Over current running ✓
• CPU and peripheral device (electronic controller) ✓
6 Manual inspection • Compressor running hour indication ✓
• Evaporator fan individual operation (high speed) ✓
• Evaporator fan individual operation (low speed) ✓
• Condenser fan individual operation ✓
• Indication of elapsed time since trip start/time resetting ✓
• Evaporator fan run-hour indication ✓
• Condenser fan run-hour indication ✓
• Controller software version indication ✓
• Temperature sensor calibration
• Elapsed days since last PTI.
• [PC] ---
Pulp temperature sensor/cargo temperature sensor calibration
Optional
• [PC] --- Header information set of data logger ✓
• [PC] --- All sensor data indication ✓
• [PC] --- Controller built-in relay output display/MV output ✓
(opening rate) indication/EV output (opening rate) indication
7 Automatic PTI • Automatic PTI (SHORT) = Operation check of components ✓
• Automatic PTI (FULL) ✓
8 Data logging • Compressor total running hour ✓
• Evaporator fan motor total running hour ✓
• Condenser fan motor total running hour ✓
• Trip data ✓
• Pulp temperature data Optional
• Cargo temperature data Optional
• Alarm logging data ✓
• Automatic PTI data ✓
• Event data ✓
9 Data retrieving • [PC] --- Alarm data ✓
(Data output) • [PC] --- Trip data ✓
• [PC] --- Automatic PTI data ✓
• [PC] --- Pulp temperature data Optional
• [PC] --- Cargo temperature data Optional
• [PC] --- Event data ✓
10 Communication • Remote monitoring Optional
• Remote control Optional
11 Power back-up ※
Even while the power is off, the following works are possible.
• Setting, Temperature setting ✓
Humidity setting Optional
Defrosting interval setting ✓
[PC] --- Container ID data setting ✓
• Saving the logger data record ✓
• Data retrieving (down loading) ✓
12 Chartless • Alarm indication function (H code) ✓
• Operation history indication function (D code) ✓
• Pull-down time indication function (P code) ✓
•
Temperature logging data indication on LCD in simple graphic chart
✓
13 G-SET mode ※To be used when power supply capacity is small.
• Energy saving operation ✓
14 Data scroll • Temperature log scroll indication function ✓
• Alarm log indication function ✓
15 Data input ※The following works are possible using the indication panel
• Container ID (No.) entering ✓
• Controller time setting ✓
16 Automatic •
Refelgerant is collected into the receiver and condensor coil.
✓
Pump down