3-2
No. Function division Function DECOS3b
5 Self-diagnosis and • Open-phase running
automatic back-up • Over current running
• CPU and peripheral device (electronic controller)
6 Manual inspection • Compressor running hour indication
• Evaporator fan individual operation (high speed)
• Evaporator fan individual operation (low speed)
• Condenser fan individual operation
• Indication of elapsed time since trip start/time resetting
• Evaporator fan run-hour indication
• Condenser fan run-hour indication
• Controller software version indication
• Temperature sensor calibration
• Elapsed days since last PTI.
• [PC] ---
Pulp temperature sensor/cargo temperature sensor calibration
Optional
• [PC] --- Header information set of data logger
• [PC] --- All sensor data indication
• [PC] --- Controller built-in relay output display/MV output
(opening rate) indication/EV output (opening rate) indication
7 Automatic PTI • Automatic PTI (SHORT) = Operation check of components
• Automatic PTI (FULL)
8 Data logging • Compressor total running hour
• Evaporator fan motor total running hour
• Condenser fan motor total running hour
• Trip data
• Pulp temperature data Optional
• Cargo temperature data Optional
• Alarm logging data
• Automatic PTI data
• Event data
9 Data retrieving • [PC] --- Alarm data
(Data output) • [PC] --- Trip data
• [PC] --- Automatic PTI data
• [PC] --- Pulp temperature data Optional
• [PC] --- Cargo temperature data Optional
• [PC] --- Event data
10 Communication • Remote monitoring Optional
• Remote control Optional
11 Power back-up
Even while the power is off, the following works are possible.
• Setting, Temperature setting
Humidity setting Optional
Defrosting interval setting
[PC] --- Container ID data setting
• Saving the logger data record
• Data retrieving (down loading)
12 Chartless • Alarm indication function (H code)
• Operation history indication function (D code)
• Pull-down time indication function (P code)
Temperature logging data indication on LCD in simple graphic chart
13 G-SET mode To be used when power supply capacity is small.
• Energy saving operation
14 Data scroll • Temperature log scroll indication function
• Alarm log indication function
15 Data input The following works are possible using the indication panel
• Container ID (No.) entering
• Controller time setting
16 Automatic
Refelgerant is collected into the receiver and condensor coil.
Pump down
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LXE10E-A14 and is the answer not in the manual?

Daikin LXE10E-A14 Specifications

General IconGeneral
BrandDaikin
ModelLXE10E-A14
CategoryHeat Pump
LanguageEnglish

Related product manuals