3-21
7. TEMPERATURE RECORD SCROLL MODE
The control sensor value record is shown in sequence (scroll) starting with the latest data. The latest
control temperatures for a maximum of 7 days are displayed.
<Mode selection procedure>
<Operation procedure>
The LED indicates the control temperature, and the LCD displays the data/time and the data record
temperature in turn. (In the partial frozen mode and frozen mode, the return air temperature is the
controlled temperature, and in the chilled mode, the supply air temperature is the control temperature.)
To pauze the scrolling action, press the or key. To continue to the next temperature record
manually, press the or key during the holding of indication, or to resume the automatically scroll
function, do not press any key for 10 seconds. To see data beginning with start again, press and hold
the key for 3 seconds.
To restore the current indication mode, press the key.
If key operation is not performed within 5 minutes, the current indication mode is resumed.
To go to the operation setting mode, press the key.
S