3-29
10. OPTIONAL FUNCTION SETTING MODE
<Key operation to enter/exit>
I/O ON I/O OFF
I/O
Power OFF
Unit OFF
All indication
lights on
(for 3 sec.)
Starting
preparation
(for 18 sec.)
1
Current
indication
(Operation state)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec.
10
Optional Function Setting
F. PTI
S. PTI
M. CHECK
for 3 sec.
To set the USDA ON/OFF and CARGO TEMPERATURE SENSOR ON/OFF:
Select "OFF (not in use)", "3 (3 USDA probes are in use)", or "4 (3
USDA probes and 1 cargo temperature sensor are in use)" on the LED
while the LCD displays "USdA".
Whenever the or key is pressed, the indication of "OFF" or "3"
or "4" is changed.
Press the key to determine the setting.
Note: When two USDA probes are connected, the setting will be
determined automatically to "3" (3 USDA probes are in use).
To set the DEHUMIDIFICATION CONTROL:
Select "ON" (conducting dehumidifying with humidity sensor) or "OFF"
(conducting no dehumidifying) on the LED while the LCD indicates "dHU".
Whenever the or key is pressed, the indication of "ON" or "OFF" is changed.
Press the key to determine the setting.
Note : This setting can be changed by key. (Refer to 3-12)
M
USDA SENSOR ON/OFF,
CARGO TEMPERATURE
SENSOR ON/OFF SETTING
DEHUMIDIFUCATION
CONTROL ON/OFF
SETTING
SS
<Key operation in this mode>
Whenever the key is pressed, the display changes.
Turn the power breaker OFF after the setting.
S
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LXE10E-A14 and is the answer not in the manual?

Daikin LXE10E-A14 Specifications

General IconGeneral
BrandDaikin
ModelLXE10E-A14
CategoryHeat Pump
LanguageEnglish

Related product manuals