4.1.2 Setting LCP Display Values
The display area is activated when the frequency converter
receives power from
mains voltage, a DC bus terminal, or
an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application.
Each display readout has a parameter associated
with it
Options are selected in the quick menu Q3-13
Display Settings
Display 2 has an alternate larger display option
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable
1.1
2
3
1.3
1.2
130BT831.10
0.0%
Off Remote Stop
1 (1)
0.00 kw0.00 A
0.0Hz
2605kWh
Status
Illustration 4.2 Display Readouts
Display Parameter number Default setting
1.1 0-20 Reference %
1.2 0-21 Motor current
1.3 0-22 Power [kW]
2 0-23 Frequency
3 0-24 kWh counter
Table 4.1 Legend to Illustration 4.2
4.1.3 Display Menu
Keys
Menu keys are used for menu access for parameter set-up,
toggling through status
display modes during normal
operation, and viewing fault log data.
130BP045.10
Status
Quick
Menu
Main
Menu
Alarm
Log
Illustration 4.3 Menu Keys
Key Function
Status Shows operational information.
In
Auto
mode,
press to toggle between
status read-out displays
Press repeatedly to scroll through each
status display
Press [Status] plus [
] or [
] to adjust the
display brightness
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu Allows access to programming parameters for
initial set up
instructions and many detailed
application instructions.
Press to access Q2 Quick Setup for
sequenced instructions to program the basic
frequency controller set up
Follow the sequence of parameters as
presented for the function set up
Main Menu Allows access to all programming parameters.
Press twice to
access top-level index
Press once to return to the last location
accessed
Press to enter a parameter number for
direct access to that parameter
Alarm Log Displays a list of current warnings, the last 10
alarms, and the
maintenance log.
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys
and press [OK].
Table 4.2 Function Description Menu Keys
User Interface
VLT
®
HVAC Drive Operating Instructions
MG11AI02 - VLT
®
is a registered Danfoss trademark
33
4 4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Table of Contents

Other manuals for Danfoss 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss 102 and is the answer not in the manual?

Danfoss 102 Specifications

General IconGeneral
BrandDanfoss
Model102
CategoryMedia Converter
LanguageEnglish

Related product manuals