4.1.4 Navigation Keys
Navigation keys are used for programming functions and
moving the display
cursor. The navigation keys also
provide speed control in local (hand) operation. Three
frequency converter status indicator lights are also located
in this area.
130BT117.10
OK
Back
Info
Warm
Alarm
On
Cancel
Illustration 4.4 Navigation Keys
Key Function
Back Reverts to the previous step or list in the menu
structure.
Cancel Cancels the last change or command as long as
the
display mode
has not changed.
Info Press for a definition of the function being
displayed.
Navigation
Keys
Use the four navigation keys to move between
items
in the
menu.
OK Use to access parameter groups or to enable a
choice.
Table 4.3 Navigation Keys Functions
Light Indicator Function
Green ON The ON light activates when the
frequency
converter receives
power
from mains voltage, a DC
bus terminal, or an external 24 V
supply.
Yellow WARN When warning conditions are met,
the yellow WARN
light comes on
and text appears in the display
area identifying the problem.
Red ALARM A fault condition causes the red
alarm light to
flash and an alarm
text is displayed.
Table 4.4 Indicator Lights Functions
4.1.5 Operation Keys
Operation keys are found at the bottom of the LCP.
130BP046.10
Hand
on
O
Auto
on
Reset
Illustration 4.5 Operation Keys
Key Function
Hand On Starts the frequency converter in local control.
Use the navigation
keys to control frequency
converter speed
An external stop signal by control input or
serial communication overrides the local hand
on
Off Stops the motor but does not remove power to
the frequency converter.
Auto
On Puts the system in remote operational mode.
Responds to an
external start command by
control terminals or serial communication
Speed reference is from an external source
Reset Resets the frequency converter manually after a
fault has been
cleared.
Table 4.5 Operation Keys Functions
4.2 Back Up and Copying Parameter
Settings
Programming data is stored internally in the frequency
converter.
The data can
be uploaded into the LCP memory
as a storage back up
Once stored in the LCP, the data can be
downloaded back into the frequency converter
Data can also be downloaded into other
frequency converters by connecting the LCP into
those units and downloading the stored settings.
(This is a quick way to program multiple units
with the same settings).
Initialisation of the frequency converter to restore
factory default settings does not change data
stored in the LCP memory
User Interface
VLT
®
HVAC Drive Operating Instructions
34 MG11AI02 - VLT
®
is a registered Danfoss trademark
44
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Table of Contents

Other manuals for Danfoss 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss 102 and is the answer not in the manual?

Danfoss 102 Specifications

General IconGeneral
BrandDanfoss
Model102
CategoryMedia Converter
LanguageEnglish

Related product manuals