1. Press [Main Menu] twice, scroll to parameter
group
5-**
Digital
In/Out
Parameter Data Set and
press [OK].
130BT768.10
2-** Brakes
3-** Reference / Ramps
4-** Limits / Warnings
5-** Digital In/Out
0.00A
Main Menu
Illustration 5.9 6-15 Terminal 53 High
Ref./Feedb. Value
2.
Scroll to parameter group
5-1* Digital Inputs and
press [OK].
130BT769.10
5-0* Digital I/O mode
5-1* Digital Inputs
5-4* Relays
5-5* Pulse Input
0.00A
Digital In/Out
5-**
Illustration 5.10 Digital In/Out
3.
Scroll
to 5-10 Terminal
18 Digital Input. Press [OK]
to access function choices. The default setting
Start is shown.
5-1*
130BT770.10
5-10 Terminal 18 Digital
Input
[
8
]] Start
0.00A
Digital Inputs
Illustration 5.11 Digital Inputs
5.4 International/North American Default
Parameter Settings
Setting 0-03 Regional Settings to [0]
International or [1]
North America changes the default settings for some
parameters. Table 5.1 lists those parameters that are
effected.
Parameter International
default
parameter
value
North American
default parameter
value
0-03
Regional
Settings
International North America
1-20 Motor Power
[kW]
See Note 1 See Note 1
1-21 Motor Power
[HP]
See Note 2 See Note 2
1-22 Motor Voltage 230 V/400 V/575 V 208 V/460 V/575 V
1-23 Motor
Frequency
50 Hz 60 Hz
3-03 Maximum
Reference
50 Hz 60 Hz
3-04 Reference
Function
Sum External/Preset
4-13 Motor Speed
High
Limit [RPM]
See Note
3 and 5
1500 PM 1800 RPM
4-14 Motor Speed
High Limit [Hz]
See Note
4
50 Hz 60 Hz
4-19 Max Output
Frequency
100 Hz 120 Hz
4-53 Warning Speed
High
1500 RPM 1800 RPM
5-12 Terminal 27
Digital
Input
Coast inverse External interlock
5-40 Function Relay Alarm No alarm
6-15 Terminal 53
High
Ref./Feedb.
Value
50 60
6-50 Terminal 42
Output
Speed
0-HighLim Speed 4-20 mA
14-20 Reset Mode
Manual reset Infinite auto reset
Table 5.1 International/North American Default Parameter Settings
Note 1: 1-20 Motor
Power [kW] is only visible when 0-03 Regional
Settings is set to [0] International.
Note 2: 1-21 Motor Power [HP], is only visible when 0-03 Regional
Settings is set to [1] North America.
Note 3: This parameter is only visible when 0-02 Motor Speed Unit is
set to [0] RPM.
Note 4: This parameter is only visible when 0-02 Motor Speed Unit is
set to [1] Hz.
Note 5: The default value depends on the number of motor poles. For
a 4 poled motor the international default value is 1500 RPM and for
a 2 poled motor 3000 RPM. The corresponding values for North
America is 1800 and 3600 RPM, respectively.
Changes made to default settings are stored and available
for viewing in the quick menu along with any
programming entered into parameters.
1. Press [Quick Menu].
2.
Scroll to Q5 Changes Made and press [OK].
About Frequency Converter P...
VLT
®
HVAC Drive Operating Instructions
38 MG11AI02 - VLT
®
is a registered Danfoss trademark
55
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Table of Contents

Other manuals for Danfoss 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss 102 and is the answer not in the manual?

Danfoss 102 Specifications

General IconGeneral
BrandDanfoss
Model102
CategoryMedia Converter
LanguageEnglish

Related product manuals