Solenoid override valve for MDC
Removal
1. Thoroughly clean external surfaces prior to removal of valve.
2. Remove the solenoid from the valve by removing the nut with a 3/4 inch hex wrench. Remove the
solenoid valve (M76) from the manifold (M75) with a 7/8 inch hex wrench.
3. Using a 5 mm internal hex wrench, remove the two screws (M78) and remove solenoid manifold
(M75) from housing. Remove and discard the gasket (M77).
Reassembly
1. Torque valve (M76) to 24 N•m [17.7 lbf•ft]. Torque solenoid nut to 6 N•m [5 lbf•ft]. Do not overtorque
the solenoid nut.
2. Install a new gasket on the control housing. Install the manifold onto the control housing, align the
gasket, and install the screws. Torque the screws to 13.5 N•m [10 lbf•ft].
Service Manual
Series 90 Pumps
Minor repair
60 520L0818 • Rev 0101 • August 2015