5.1.2 0-** Operation and Display
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
0-0* Basic Settings
0-01 Language [0] English 1 set-up TRUE - Uint8
0-02 Motor Speed Unit [1] Hz 2 set-ups FALSE - Uint8
0-03 Regional Settings ExpressionLimit 2 set-ups FALSE - Uint8
0-04 Operating State at Power-up [0] Resume All set-ups TRUE - Uint8
0-1* Set-up Operations
0-10 Active Set-up [1] Set-up 1 1 set-up TRUE - Uint8
0-11 Programming Set-up [9] Active Set-up All set-ups TRUE - Uint8
0-12 This Set-up Linked to [0] Not linked All set-ups FALSE - Uint8
0-13 Readout: Linked Set-ups 0 N/A All set-ups FALSE 0 Uint16
0-14 Readout: Prog. Set-ups / Channel 0 N/A All set-ups TRUE 0 Int32
0-2* LCP Display
0-20 Display Line 1.1 Small 1602 All set-ups TRUE - Uint16
0-21 Display Line 1.2 Small 1614 All set-ups TRUE - Uint16
0-22 Display Line 1.3 Small 1610 All set-ups TRUE - Uint16
0-23 Display Line 2 Large 1613 All set-ups TRUE - Uint16
0-24 Display Line 3 Large 1502 All set-ups TRUE - Uint16
0-25 My Personal Menu ExpressionLimit 1 set-up TRUE 0 Uint16
0-3* LCP Custom Readout
0-30 Custom Readout Unit [1] % All set-ups TRUE - Uint8
0-31 Custom Readout Min Value ExpressionLimit All set-ups TRUE -2 Int32
0-32 Custom Readout Max Value
100 CustomRea-
doutUnit All set-ups TRUE -2 Int32
0-37 Display Text 1 0 N/A 1 set-up TRUE 0 VisStr[25]
0-38 Display Text 2 0 N/A 1 set-up TRUE 0 VisStr[25]
0-39 Display Text 3 0 N/A 1 set-up TRUE 0 VisStr[25]
0-4* LCP Keypad
0-40 [Hand on] Key on LCP [1] Enabled All set-ups TRUE - Uint8
0-41 [O] Key on LCP [1] Enabled All set-ups TRUE - Uint8
0-42 [Auto on] Key on LCP [1] Enabled All set-ups TRUE - Uint8
0-43 [Reset] Key on LCP [1] Enabled All set-ups TRUE - Uint8
0-5* Copy/Save
0-50 LCP Copy [0] No copy All set-ups FALSE - Uint8
0-51 Set-up Copy [0] No copy All set-ups FALSE - Uint8
0-6* Password
0-60 Main Menu Password 100 N/A 1 set-up TRUE 0 Int16
0-61 Access to Main Menu w/o Password [0] Full access 1 set-up TRUE - Uint8
0-65 Personal Menu Password 200 N/A 1 set-up TRUE 0 Int16
0-66
Access to Personal Menu w/o
Password [0] Full access 1 set-up TRUE - Uint8
0-67 Bus Access Password 0 N/A All set-ups TRUE 0 Uint16
0-7* Clock Settings
0-70 Date and Time ExpressionLimit All set-ups TRUE 0 TimeOfDay
0-71 Date Format ExpressionLimit 1 set-up TRUE - Uint8
0-72 Time Format ExpressionLimit 1 set-up TRUE - Uint8
0-74 DST/Summertime [0] O 1 set-up TRUE - Uint8
0-76 DST/Summertime Start ExpressionLimit 1 set-up TRUE 0 TimeOfDay
0-77 DST/Summertime End ExpressionLimit 1 set-up TRUE 0 TimeOfDay
0-79 Clock Fault ExpressionLimit 1 set-up TRUE - Uint8
0-81 Working Days ExpressionLimit 1 set-up TRUE - Uint8
Parameter Lists
VLT
®
HVAC Drive FC 102
224 Danfoss A/S © 03/2015 All rights reserved. MG11CE02
55

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals