5.1.12 11-** LonWorks
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
11-0* LonWorks ID
11-00 Neuron ID 0 N/A All set-ups TRUE 0 OctStr[6]
11-1* LON Functions
11-10 Drive Prole [0] VSD prole All set-ups TRUE - Uint8
11-15 LON Warning Word 0 N/A All set-ups TRUE 0 Uint16
11-17 XIF Revision 0 N/A All set-ups TRUE 0 VisStr[5]
11-18 LonWorks Revision 0 N/A All set-ups TRUE 0 VisStr[5]
11-2* LON Param. Access
11-21 Store Data Values [0] O All set-ups TRUE - Uint8
5.1.13 13-** Smart Logic Controller
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
13-0* SLC Settings
13-00 SL Controller Mode ExpressionLimit 2 set-ups TRUE - Uint8
13-01 Start Event ExpressionLimit 2 set-ups TRUE - Uint8
13-02 Stop Event ExpressionLimit 2 set-ups TRUE - Uint8
13-03 Reset SLC [0] Do not reset SLC All set-ups TRUE - Uint8
13-1* Comparators
13-10 Comparator Operand ExpressionLimit 2 set-ups TRUE - Uint8
13-11 Comparator Operator ExpressionLimit 2 set-ups TRUE - Uint8
13-12 Comparator Value ExpressionLimit 2 set-ups TRUE -3 Int32
13-2* Timers
13-20 SL Controller Timer ExpressionLimit 1 set-up TRUE -3 TimD
13-4* Logic Rules
13-40 Logic Rule Boolean 1 ExpressionLimit 2 set-ups TRUE - Uint8
13-41 Logic Rule Operator 1 ExpressionLimit 2 set-ups TRUE - Uint8
13-42 Logic Rule Boolean 2 ExpressionLimit 2 set-ups TRUE - Uint8
13-43 Logic Rule Operator 2 ExpressionLimit 2 set-ups TRUE - Uint8
13-44 Logic Rule Boolean 3 ExpressionLimit 2 set-ups TRUE - Uint8
13-5* States
13-51 SL Controller Event ExpressionLimit 2 set-ups TRUE - Uint8
13-52 SL Controller Action ExpressionLimit 2 set-ups TRUE - Uint8
5.1.14 14-** Special Functions
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
14-0* Inverter Switching
14-00 Switching Pattern ExpressionLimit All set-ups TRUE - Uint8
14-01 Switching Frequency ExpressionLimit All set-ups TRUE - Uint8
14-03 Overmodulation [0] O All set-ups FALSE - Uint8
14-04 PWM Random [0] O All set-ups TRUE - Uint8
14-1* Mains On/O
14-10 Mains Failure [0] No function All set-ups FALSE - Uint8
14-11 Mains Voltage at Mains Fault ExpressionLimit All set-ups TRUE 0 Uint16
14-12 Function at Mains Imbalance [0] Trip All set-ups TRUE - Uint8
14-2* Reset Functions
Parameter Lists Programming Guide
MG11CE02 Danfoss A/S © 03/2015 All rights reserved. 233
5 5

Table of Contents

Other manuals for Danfoss VLT AHF 005