6-40 Terminal X30/12 Low Voltage 0.07 V All set-ups TRUE -2 Int16
6-41 Terminal X30/12 High Voltage 10 V All set-ups TRUE -2 Int16
6-44 Term. X30/12 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
6-45 Term. X30/12 High Ref./Feedb. Value 100 N/A All set-ups TRUE -3 Int32
6-46 Term. X30/12 Filter Time Constant 0.001 s All set-ups TRUE -3 Uint16
6-47 Term. X30/12 Live Zero [1] Enabled All set-ups TRUE - Uint8
6-5* Analog Output 42
6-50 Terminal 42 Output ExpressionLimit All set-ups TRUE - Uint8
6-51 Terminal 42 Output Min Scale 0 % All set-ups TRUE -2 Int16
6-52 Terminal 42 Output Max Scale 100 % All set-ups TRUE -2 Int16
6-53 Terminal 42 Output Bus Control 0 % All set-ups TRUE -2 N2
6-54 Terminal 42 Output Timeout Preset 0 % 1 set-up TRUE -2 Uint16
6-55 Analog Output Filter [0] O 1 set-up TRUE - Uint8
6-6* Analog Output X30/8
6-60 Terminal X30/8 Output [0] No operation All set-ups TRUE - Uint8
6-61 Terminal X30/8 Min. Scale 0 % All set-ups TRUE -2 Int16
6-62 Terminal X30/8 Max. Scale 100 % All set-ups TRUE -2 Int16
6-63 Terminal X30/8 Output Bus Control 0 % All set-ups TRUE -2 N2
6-64 Terminal X30/8 Output Timeout Preset 0 % 1 set-up TRUE -2 Uint16
5.1.9 8-** Communication and Options
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
8-0* General Settings
8-01 Control Site ExpressionLimit All set-ups TRUE - Uint8
8-02 Control Source ExpressionLimit All set-ups TRUE - Uint8
8-03 Control Timeout Time ExpressionLimit 1 set-up TRUE -1 Uint32
8-04 Control Timeout Function [0] O 1 set-up TRUE - Uint8
8-05 End-of-Timeout Function [1] Resume set-up 1 set-up TRUE - Uint8
8-06 Reset Control Timeout [0] Do not reset All set-ups TRUE - Uint8
8-07 Diagnosis Trigger [0] Disable 2 set-ups TRUE - Uint8
8-08 Readout Filtering ExpressionLimit All set-ups TRUE - Uint8
8-1* Control Settings
8-10 Control Prole [0] FC prole All set-ups TRUE - Uint8
8-13 Congurable Status Word STW [1] Prole Default All set-ups TRUE - Uint8
8-3* FC Port Settings
8-30 Protocol ExpressionLimit 1 set-up TRUE - Uint8
8-31 Address ExpressionLimit 1 set-up TRUE 0 Uint8
8-32 Baud Rate ExpressionLimit 1 set-up TRUE - Uint8
8-33 Parity / Stop Bits ExpressionLimit 1 set-up TRUE - Uint8
8-34 Estimated cycle time 0 ms 2 set-ups TRUE -3 Uint32
8-35 Minimum Response Delay ExpressionLimit 1 set-up TRUE -3 Uint16
8-36 Maximum Response Delay ExpressionLimit 1 set-up TRUE -3 Uint16
8-37 Maximum Inter-Char Delay ExpressionLimit 1 set-up TRUE -5 Uint16
8-4* FC MC protocol set
8-40 Telegram Selection
[1] Standard
telegram 1 2 set-ups TRUE - Uint8
8-42 PCD Write Conguration ExpressionLimit 2 set-ups TRUE - Uint16
8-43 PCD Read Conguration ExpressionLimit 2 set-ups TRUE - Uint16
8-5* Digital/Bus
8-50 Coasting Select [3] Logic OR All set-ups TRUE - Uint8
8-52 DC Brake Select ExpressionLimit All set-ups TRUE - Uint8
8-53 Start Select [3] Logic OR All set-ups TRUE - Uint8