26-30 Terminal X42/5 Low Voltage 0.07 V All set-ups TRUE -2 Int16
26-31 Terminal X42/5 High Voltage 10 V All set-ups TRUE -2 Int16
26-34 Term. X42/5 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
26-35 Term. X42/5 High Ref./Feedb. Value 100 N/A All set-ups TRUE -3 Int32
26-36 Term. X42/5 Filter Time Constant 0.001 s All set-ups TRUE -3 Uint16
26-37 Term. X42/5 Live Zero [1] Enabled All set-ups TRUE - Uint8
26-4* Analog Out X42/7
26-40 Terminal X42/7 Output [0] No operation All set-ups TRUE - Uint8
26-41 Terminal X42/7 Min. Scale 0 % All set-ups TRUE -2 Int16
26-42 Terminal X42/7 Max. Scale 100 % All set-ups TRUE -2 Int16
26-43 Terminal X42/7 Bus Control 0 % All set-ups TRUE -2 N2
26-44 Terminal X42/7 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
26-5* Analog Out X42/9
26-50 Terminal X42/9 Output [0] No operation All set-ups TRUE - Uint8
26-51 Terminal X42/9 Min. Scale 0 % All set-ups TRUE -2 Int16
26-52 Terminal X42/9 Max. Scale 100 % All set-ups TRUE -2 Int16
26-53 Terminal X42/9 Bus Control 0 % All set-ups TRUE -2 N2
26-54 Terminal X42/9 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
26-6* Analog Out X42/11
26-60 Terminal X42/11 Output [0] No operation All set-ups TRUE - Uint8
26-61 Terminal X42/11 Min. Scale 0 % All set-ups TRUE -2 Int16
26-62 Terminal X42/11 Max. Scale 100 % All set-ups TRUE -2 Int16
26-63 Terminal X42/11 Bus Control 0 % All set-ups TRUE -2 N2
26-64 Terminal X42/11 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
5.1.25 30-** Special Features
Param
eter #
Parameter description Default value 4 set-up Change during
operation
Conversion
index
Type
30-2* Adv. Start Adjust
30-22 Locked Rotor Detection ExpressionLimit All set-ups TRUE - Uint8
30-23 Locked Rotor Detection Time [s] ExpressionLimit All set-ups TRUE -2 Uint8
Parameter Lists
VLT
®
HVAC Drive FC 102
244 Danfoss A/S © 03/2015 All rights reserved. MG11CE02
55

Table of Contents

Other manuals for Danfoss VLT AHF 005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AHF 005 and is the answer not in the manual?

Danfoss VLT AHF 005 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AHF 005
CategoryDC Drives
LanguageEnglish

Related product manuals