4 How to Install
4.1 How to Get Started
This chapter covers mechanical and electrical installations
to and from power terminals and control card terminals.
Electrical installation of options is described in the relevant
Operating Instructions and Design Guides.
The frequency converter is designed to achieve a quick
and EMC-correct installation by following the steps
described below.
WARNING
Read the safety instructions before installing the unit.
Failure to follow recommendations could result in death or
serious injury.
Mechanical Installation
Mechanical mounting
Electrical Installation
Connection to Mains and Protecting Earth
Motor connection and cables
Fuses and circuit breakers
Control terminals - cables
Quick Setup
Local Control Panel (LCP) of frequency converter
Local Control Panel of filter
Automatic Motor Adaptation, AMA
Programming
Frame size is depending on enclosure type, power range,
and mains voltage
M
3
96 97 9998
37
91 92 93
12
L1
W PEVU
F1
L2
L3
PE
130BA015.13
1
18
81 82
R+R-
95
55
50
53
27
88
89
DC- DC+
L1 L2 PEL3
Illustration 4.1 Diagram showing basic installation including
mains, motor, start/stop key, and potentiometer for speed
adjustment.
4.2 Pre-installation
4.2.1 Planning the Installation Site
CAUTION
Before performing the installation it is important to plan
the installation of the frequency converter. Neglecting this
may result in extra work during and after installation.
Select the best possible operation site by considering the
following (see details on the following pages, and the
respective VLT AutomationDrive Design Guides):
Ambient operating temperature
Installation method
How to cool the unit
Position of the frequency converter
Cable routing
Ensure the power source supplies the correct
voltage and necessary current
Ensure that the motor current rating is within the
maximum current from the frequency converter
If the frequency converter is without built-in
fuses, ensure that the external fuses are rated
correctly.
How to Install VLT Automation Low Harmonic Drive Operating Instructions
MG34O202 - VLT
®
is a registered Danfoss trademark 13
4 4

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals