3.2.1.3 Short-cycle Protection
The VLT® Compressor Drive CDS 803 includes a compressor short-cycling protection that prevents mechanical wear to the compres-
sor and reduces the risk of oil shortage caused by starting and stopping too often. The short-cycle protection consists of 2 timers:
The interval between starts ensures that a new start first becomes active when the start time has expired.
The minimum run time ensures that the compressor always runs for a defined minimum time before stopping the compressor.
Warning 96, Start Delay is shown in the display if there is a start signal and the INTERVAL BETWEEN STARTS has not expired.
Warning 97, Stop Delay is shown in the display if there is a stop signal and the MINIMUM RUNTIME has not expired.
e30bj250.10
Speed
Start signal
On
Off
Time
Time
Interval between
Starts expires
Warning 96
“Start Delay”
Illustration 4: Short Cycle Protection, Start Delay
e30bj251.10
Speed
Start signal
On
Off
Time
Time
Minimum run time expired
Warning 97
“Stop Delay”
Illustration 5: Short Cycle Protection, Stop Delay
3.2.1.4 Anti-reverse Protection
The anti-reverse protection function prevents the compressor scroll set from running in the wrong direction during stop.
AJ330233902305en-000201 / 130R059614 | Danfoss A/S © 2021.05
Product Overview
VLT® Compressor Drive CDS 803
Design Guide

Table of Contents

Other manuals for Danfoss VLT CDS 803

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CDS 803 and is the answer not in the manual?

Danfoss VLT CDS 803 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CDS 803
CategoryDC Drives
LanguageEnglish

Related product manuals