Page #53 background imageLoading...
Page #53 background image
1
Ground wire
2
Shield
3
AC mains supply
4
Drive
5
Shielded motor cable
6
Motor
C
S
Possible shunt parasitic capacitance paths (varies
with different installations)
I
1
Common-mode leakage current
I
2
Shielded motor cable
I
3
Safety ground (4
th
conductor in motor cables)
I
4
Unintended common-mode current
6.5.1 EMC Emission Test Results
The following test results have been obtained using a system with a drive, a shielded control cable, a control box with potentiome-
ter, and a shielded motor cable.
Table 17: EMC Emission Test Results
Conduct emission
Maximum shielded cable length [m (ft)]
Radiated emission
EN 55011
Class A Group 2
Industrial environ-
ment
Class A Group 1
Industrial environ-
ment
Class B
Housing, trades,
and light indus-
tries
Class A Group
2
Industrial envi-
ronment
Class A Group
1
Industrial envi-
ronment
Class B
Housing,
trades, and
light industries
EN/IEC
61800-3
Category C3
Second environ-
ment Industrial
Category C2
First environment
Home and office
Category C1
First environ-
ment Home and
office
Category C3
Second envi-
ronment Indus-
trial
Category C2
First environ-
ment Home
and office
Category C1
First environ-
ment Home
and office
External
RFI filter
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
H4 RFI filter (EN 55011 A1, EN/IEC61800-3 C2)
6.0– 10 kW
(8.0– 15
hp)
25 (82)
50 (164)
20 (66)
Yes
Yes
No
H2 RFI filter (EN 55011 A2, EN/IEC 61800-3 C3)
18–30 kW
(25– 40
hp)
5 (16.4)
Yes
No
No
6.5.2 Emission Requirements
According to the EMC product standard for AC drives, EN/IEC 61800-3:2004, the EMC requirements depend on the intended use of
the drive. Four categories are defined in the EMC product standard. The definitions of the 4 categories together with the require-
ments for mains supply voltage conducted emissions are given in Table 18.
AJ330233902305en-000201 / 130R0596 | 53Danfoss A/S © 2021.05
Electrical Installation
Considerations
VLT® Compressor Drive CDS 803
Design Guide

Table of Contents

Other manuals for Danfoss VLT CDS 803

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT CDS 803 and is the answer not in the manual?

Danfoss VLT CDS 803 Specifications

General IconGeneral
BrandDanfoss
ModelVLT CDS 803
CategoryDC Drives
LanguageEnglish

Related product manuals