10.2.12 Balance/High Frequency Card
To remove or reinstall the balance/high frequency card, use
the following steps. See Illustration 10.13 and
Illustration 10.14.
Disassembly in 240/400 V AC units
1. Remove the power terminal mounting plate. Refer
to chapter 10.2.9 Power Terminal Mounting Plate.
2. Unplug the cable from the MK100 connector on
the balance/high frequency card.
3. Remove 1 standoîš‚ (8 mm) from the corner of the
card.
4. Remove 2 nuts (8 mm) and 1 screw (T25) from
the card. Two of the fasteners also hold in place
the DC(+) and DC(-) wires.
5. Remove the balance/high frequency card and
insulator sheet from the drive.
Reassembly in 240/400 V AC units
Tighten hardware according to chapter 14.1 Fastener Torque
Ratings.
1. Position the insulator sheet and balance/high
frequency card in the drive.
2. Fasten 2 nuts (8 mm) and 1 screw (T25) in the
card. Two of the nuts also hold in place the DC(+)
and DC(-) wires.
3. Secure 1
standoîš‚ (8 mm) in the corner of the
card.
4. Attach the cable to the MK100 connector on the
balance/high frequency card.
5. Replace the power terminal mounting plate. Refer
to chapter 10.2.9 Power Terminal Mounting Plate.
Disassembly in 690 V AC units
1. Remove the power terminal mounting plate. Refer
to chapter 11.2.11 Power Terminal Mounting Plate.
2. Unplug the cable from the MK100 connector on
the balance/high frequency card.
3. Remove 1 standoîš‚ (8 mm) from the corner of the
card.
4. Remove 3 nuts (8 mm) and 1 screw (T20) from
the card. One of the nuts and the screw also hold
in place the DC(+) and DC(-) wires.
5. Remove the balance/high frequency card and
insulator sheet from the drive.
Reassembly in 690 V AC units
Tighten hardware according to chapter 14.1 Fastener Torque
Ratings.
1. Position the insulator sheet and balance/high
frequency card in the drive.
2. Fasten 3 nuts (8 mm) and 1 screw (T20) in the
card. One of the nuts and the screw also hold in
place the DC(+) and DC(-) wires.
3. Secure 1 standoîš‚ (8 mm) in the corner of the
card.
4. Attach the cable to the MK100 connector on the
balance/high frequency card.
5. Replace the power terminal mounting plate. Refer
to chapter 11.2.11 Power Terminal Mounting Plate.
D1h/D3h/D5h/D6h/J8 Drive Di...
VLT
®
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9
146 Danfoss A/S © 02/2019 All rights reserved. MG94A502
1010

Table of Contents

Other manuals for Danfoss VLT FC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC Series and is the answer not in the manual?

Danfoss VLT FC Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC Series
CategoryDC Drives
LanguageEnglish

Related product manuals