13-10 Comparator Operand
Option: Function:
[4] Motor Current
[6] Motor power
[7] Motor voltage
[12] Analog input AI53
[13] Analog input AI54
[18] Pulse input FI29
[19] Pulse input FI33
[20] Alarm number
[30] Counter A
[31] Counter B
13-11 Comparator Operator
Option: Function:
Select the operator to be used in the
comparison. This is an array parameter
containing comparator operators 0–5.
[0] Less Than (<) The result of the evaluation is TRUE, when
the variable selected in
parameter 13-10 Comparator Operand is
smaller than the xed value in
parameter 13-12 Comparator Value. The result
is FALSE, if the variable selected in
parameter 13-10 Comparator Operand is
greater than the xed value in
parameter 13-12 Comparator Value.
[1]
*
Approx.Equal
(~)
The result of the evaluation is TRUE, when
the variable speed selected in
parameter 13-10 Comparator Operand is
approximately equal to the xed value in
parameter 13-12 Comparator Value.
[2] Greater Than
(>)
Inverse logic of [0] Less Than (<).
13-12 Comparator Value
Range: Function:
0* [-9999 -
9999 ]
Enter the trigger level for the variable that is
monitored by this comparator. This is an
array parameter containing comparator
values 0–5.
13-20 SL Controller Timer
Range: Function:
0 s* [0 - 3600
s]
Enter the value to dene the duration of the
FALSE output from the programmed timer. A
timer is only FALSE if it is started by an action
(for example [29] Start timer 1) and until the
given timer value has elapsed.
13-40 Logic Rule Boolean 1
Option: Function:
Select the 1st boolean (TRUE or
FALSE) input for the selected logic
rule. See parameter 13-01 Start Event
([0]–[61]) and parameter 13-02 Stop
Event ([70]–[74]) for further
description.
[0] * False
[1] True
[2] Running
[3] In range
[4] On reference
[7] Out of current range
[8] Below I low
[9] Above I high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[39] Start command
[40] Drive stopped
[42] Auto Reset Trip
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[83] Broken Belt
Parameter Descriptions
VLT
®
Midi Drive FC 280
86 Danfoss A/S © 12/2015 All rights reserved. MG07C102
44

Other manuals for Danfoss VLT Midi Drive FC 280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Midi Drive FC 280 and is the answer not in the manual?

Danfoss VLT Midi Drive FC 280 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Midi Drive FC 280
CategoryDC Drives
LanguageEnglish

Related product manuals