16 STS320
CHAPTER 4
SOFTWARE CONFIGURATION
There are two main methods that can be used to complete the STS320 installation.
The first regards stations that do not need any application specific parameter configura-
tion. The factory default configuration is sufficient and the only necessary steps are to
align the
Master IP Address to the Host LAN through a web browser using the Web Dis-
covery feature, then backup the configuration through the CBX500 menu.
The second method requires installation of the DL.CODE configuration program.
T
hrough DL.CODE, IP Addresses are aligned, application specific parameters are config-
ured, and backup procedures are performed both to the external storage device
(BM100), as w
ell as to a file.
STS320 DEFAULT CONFIGURATION
Default IP Address
192.168.3.100
Code symbologies
CODE128, CODE39, INT2OF5 (min. 8 digits)
Layout type
Synchronized
Operating mode
Phase mode
Phase ON: Input 1 - Leading Edge
Phase OFF: Input 2 - Trailing Edge
Acquisition trigger
Periodic (25 ms)
Data collection type
Code combination (1 expected code)
Output
• Good Read: Output 2, Green Spot, 360° Green Feedback
• No Read: Output 1, Red Spot, 360° Red Feedback
• Configuration Mode: 360° Blue Feedback
Output Message 1
Event Type: Good Read, Output Channel: TCP Server (port 51236),
Message content: <STX><CodeContent><CR><LF>
Output Message 2
Event Type: No Read, Output Channel, TCP Server (port 51236),
Message content: <STX><CAN><CR><LF>
CONFIGURATION USING WEB DISCOVERY
Devices can be discovered via web interface. To do this, from either the Host PC or con-
figuration PC connected to the network, open your browser and go to http://data-
logic.local/.