Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
Remind codes
1 = yellow1 = yellow
2 = green2 = green
3 = yellow3 = yellow
4 = red4 = red
If one or more of the remind codes are lit for
a cow, this means that a remind code is set
in the system processor or on the MPCII.
With AlfaDast installed LED 4 (red) is lit
when the strip function is activated.
In stand-alone installations is remind LED 1
(yellow) used to indicate that the milk buffer
is full. The LED is lit when the 29th milk
weight has been put in. 30 milk weights can
be stored in the buffer. Input of another milk
weight will then throw out the first stored
weight.
Milk phase
• Green steady – indicates high milk flow in
the main milking phase
• Green flashing – indicates low milk flow in
the post milking phase
Communication interrupted
The stall unit checks constantly if the
communication with the system processor is
in progress.
Red steady indicates that the
communication with the system processor is
broken.
Note! There is a time-out of 20 seconds
from the moment the communication is
interrupted until the LED is lit. Wait for
time-out!
Functions
F0 – Memory lock
System
Press F, 0, and ↑ to lock the system
processor memory, or wait 15 minutes for
time-out.
F1 – Go to milking mode
Stand-alone
To start milking session on this MPCII only,
press F, 1, and ↑.
58(94)