Operation
DeLaval milking point controller MPCII
94381001.pdf2006-07-20
Legend LegendLegend Legend
1 Pre milking phase A Duration of post-milking1 Pre milking phase A Duration of post-milking
2 Main milking phase B Time between shut-off and cluster
take-off
2 Main milking phase B Time between shut-off and cluster
take-off
3 Post milking phase C Time between take-off and milk sweep3 Post milking phase C Time between take-off and milk sweep
4 Cluser take-off D Duration of milk sweep4 Cluser take-off D Duration of milk sweep
5 Milk flow E Manual forced vacuum duration5 Milk flow E Manual forced vacuum duration
5.1 Low milk flow limit F Time-out in low flow5.1 Low milk flow limit F Time-out in low flow
6 Pulsation G Vacuum delay6 Pulsation G Vacuum delay
7 Duovac, Vacuum reduction H Auto forced vacuum delay7 Duovac, Vacuum reduction H Auto forced vacuum delay
8 Duovac, Auto forced high vaccum ① See sections "F62 – Options" and
"F63 – Limits, timers, and options"
below
8 Duovac, Auto forced high vaccum ① See sections "F62 – Options" and
"F63 – Limits, timers, and options"
below
9 ACR, Retraction9 ACR, Retraction
10 Shut-off, Vacuum shut-off10 Shut-off, Vacuum shut-off
11 Take-off limit11 Take-off limit
12 ISO12 ISO
13 Machine on-time13 Machine on-time
F62 – Options
F321
Auto take-off. If an automatic take-off
device has been installed, set this
parameter to YES (= 1)
F322
Milk sweep. See ① in the diagram above. If
this parameter is programmed YES (= 1),
the vacuum shut-off will be open a short
period during the take-off phase. The milk in
the milk tube will then be sucked into the
milk meter.
F323
AlfaDast. If AlfaDast is used as a take-off
device, this parameter shall be set to YES
(= 1). Note! Auto take-off (F62 + F321)
must be set to YES (= 1) as well.
F324
Auto-forced high vacuum. If Duovac has
been installed, the Duovac will automatically
be forced to high vacuum during
pre-milking, if this parameter is set to YES
(= 1).
71(94)