90 Troubleshooting Your System
6
Ensure that the interface cable is securely connected to the optical drive and to the controller.
7
Ensure that a power cable is properly connected to the drive.
8
Close the system. See "Closing the System" on page 47.
9
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
If the problem is not resolved, see "Getting Help" on page 103.
Troubleshooting a Hard Drive
Problem
Device driver error.
One or more hard drives not recognized by the system.
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up
all files on the hard drive.
1
Run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on page 93.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
2
If you are experiencing problems with multiple hard drives, skip to step 5. For a problem with a single
hard drive, continue to the next step.
3
If your system has a SAS RAID controller, perform the following steps.
a
Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.
See the documentation supplied with the host adapter for information about the configuration
utility.
b
Ensure that the hard drive has been configured correctly for the RAID.
c
Exit the configuration utility and allow the system to boot to the operating system.
4
Ensure that the required device drivers for your SAS controller card or SAS RAID controller are
installed and are configured correctly. See the operating system documentation for more information.
5
Check the System Setup program to verify that the SAS controller is enabled and the hard drives
connected to the controller are detected.
6
Check the cable connections inside the system:
a
Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.

Table of Contents

Other manuals for Dell PowerEdge 860

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 860 and is the answer not in the manual?

Dell PowerEdge 860 Specifications

General IconGeneral
ChipsetIntel 3000
Form Factor1U Rack
Processor SocketLGA 775
Number of Processors Supported1
Memory Slots4
ProcessorIntel Xeon 3000 series
MemoryUp to 8GB
RAID SupportPERC 5/i
NetworkEmbedded Broadcom Gigabit Ethernet
Memory TypeDDR2
Hard Drive InterfaceSATA
Maximum Internal StorageUp to 2TB
Power Supply305W
Operating System SupportRed Hat Linux