Installing System Components 111
10
Replace the
cooling shroud
. See "Installing the Cooling Shroud" on
page 102.
11
Close the system. See "Closing the System" on page 79.
12
Start up the system, press <F2> to enter the System Setup program, and
check the
System Memory
setting on the main System Setup screen.
The system should have already changed the value to reflect the newly
installed memory.
13
If the value is incorrect, one or more of the memory modules may not be
installed properly. Repeat step 2 through step 12 of this procedure, checking to
ensure that the memory modules are firmly seated in their sockets.
14
Run the system memory test in the system diagnostics. See "Running the
Embedded System Diagnostics" on page 162.
Removing Memory Modules
WARNING: The memory modules are hot to touch for some time after the system has
been powered down. Allow time for the memory modules to cool before handling
them. Handle the memory modules by the card edges and avoid touching the
components on the memory module.
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your product
documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty.
Read and follow the safety instructions that came with the product.
1
Turn off the system, including any attached peripherals, and disconnect the
system from the electrical outlet.
2
Open the system. See "Opening the System" on page 78.
3
Remove the
cooling shroud
. See "Removing the Cooling Shroud" on
page 101.
4
Locate the memory module sockets. See
Figure 6-1
.
5
Press down and out on the ejectors on each end of the socket until the memory
module pops out of the socket. See Figure 3-15.
Handle each memory module only on either card edge, making sure not to
touch the middle of the memory module.
6
Replace the
cooling shroud
. See "Installing the Cooling Shroud" on page 102.
R310HOM.book Page 111 Thursday, March 4, 2010 1:03 AM

Table of Contents

Other manuals for Dell PowerEdge R310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R310 and is the answer not in the manual?

Dell PowerEdge R310 Specifications

General IconGeneral
Tcase72.7 °C
Bus typeDMI
SteppingB1
FSB ParityNo
Processor codeSLBJH
Processor cache8 MB
Processor cores4
Processor modelX3470
System bus rate2.5 GT/s
Processor seriesIntel Xeon 3400 Series
Processor socketLGA 1156 (Socket H)
Processor threads8
Processor codenameLynnfield
Motherboard chipsetIntel® 3420
Processing Die size296 mm²
Processor frequency2.93 GHz
Processor cache typeSmart Cache
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus- MHz
Processor boost frequency3.6 GHz
Processor operating modes64-bit
ECC supported by processorYes
PCI Express configurations1x16, 2x8, 4x4
Supported instruction setsSSE4.2
Thermal Design Power (TDP)95 W
Number of processors installed1
CPU multiplier (bus/core ratio)22
Maximum number of PCI Express lanes16
Memory types supported by processorDDR3-SDRAM
Number of Processing Die Transistors774 M
Memory channels supported by processorDual
Memory clock speeds supported by processor800, 1066, 1333 MHz
Memory bandwidth supported by processor (max)21 GB/s
Maximum internal memory supported by processor32 GB
HDD size3.5 \
Optical drive typeDVD-RW
Total storage capacity500 GB
Maximum storage capacity8 TB
Number of HDDs installed-
Memory slots6x DIMM
Internal memory2 GB
Graphics cardG200eW
LAN controllerBroadcom BCM5716
Networking featuresGigabit Ethernet
PS/2 ports quantity0
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express slots version2.0
Power supply350 W
Compatible operating systemsWindows Server Novell Linux Solaris10
Chassis typeRack (1U)
Processor ARK ID42932
Intel® Turbo Boost Technology1.0
Weight and Dimensions IconWeight and Dimensions
Depth610 mm
Width434 mm
Height42.4 mm