About Your System 37
Solving Problems Described by LCD Status Messages (Optional)
The code and text on the LCD can often specify a very precise fault condition
that is easily corrected. For example, if the code E1418
CPU_1_Presence
appears, you know that a microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related
errors occur. For example, if you receive a series of messages indicating
multiple voltage faults, you might determine that the problem is a failing
power supply.
Removing LCD Status Messages (Optional)
For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range,
the LCD displays the fault; when the temperature returns to the acceptable
range, the message is removed from the LCD. For other faults, you must take
action to remove the message from the display:
W1627 Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power
than what the power
supply can provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
W1628 Performance
degraded.
Check PSU and
system
configuration.
The system configuration
requires more power
than what the power
supply can provide, but it
can boot if throttled.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
R310HOM.book Page 37 Thursday, March 4, 2010 1:03 AM

Table of Contents

Other manuals for Dell PowerEdge R310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R310 and is the answer not in the manual?

Dell PowerEdge R310 Specifications

General IconGeneral
Tcase72.7 °C
Bus typeDMI
SteppingB1
FSB ParityNo
Processor codeSLBJH
Processor cache8 MB
Processor cores4
Processor modelX3470
System bus rate2.5 GT/s
Processor seriesIntel Xeon 3400 Series
Processor socketLGA 1156 (Socket H)
Processor threads8
Processor codenameLynnfield
Motherboard chipsetIntel® 3420
Processing Die size296 mm²
Processor frequency2.93 GHz
Processor cache typeSmart Cache
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus- MHz
Processor boost frequency3.6 GHz
Processor operating modes64-bit
ECC supported by processorYes
PCI Express configurations1x16, 2x8, 4x4
Supported instruction setsSSE4.2
Thermal Design Power (TDP)95 W
Number of processors installed1
CPU multiplier (bus/core ratio)22
Maximum number of PCI Express lanes16
Memory types supported by processorDDR3-SDRAM
Number of Processing Die Transistors774 M
Memory channels supported by processorDual
Memory clock speeds supported by processor800, 1066, 1333 MHz
Memory bandwidth supported by processor (max)21 GB/s
Maximum internal memory supported by processor32 GB
HDD size3.5 \
Optical drive typeDVD-RW
Total storage capacity500 GB
Maximum storage capacity8 TB
Number of HDDs installed-
Memory slots6x DIMM
Internal memory2 GB
Graphics cardG200eW
LAN controllerBroadcom BCM5716
Networking featuresGigabit Ethernet
PS/2 ports quantity0
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express slots version2.0
Power supply350 W
Compatible operating systemsWindows Server Novell Linux Solaris10
Chassis typeRack (1U)
Processor ARK ID42932
Intel® Turbo Boost Technology1.0
Weight and Dimensions IconWeight and Dimensions
Depth610 mm
Width434 mm
Height42.4 mm

Related product manuals