AH Motion Controller Operation Manual
7-20
_7
not be valid, and the Valid output will be set to False. The Valid output in a motion control function block will not be
True until the error occurring in the motion control function block is eliminated, and output data/states become valid.
7.7.2 Timing Diagram for Input/Outputs
Situation 1: The execution of the motion control function block is interrupted.
Situation 2: An error occurs in the motion control function block.
Situation 3: The execution of the motion control function block is complete normally.
Situation 1: The motion control function block is executed normally.
Situation 2: An error occurs in the motion control function block.