Chapter 8 CIP Object
8-27
Instance
Attribute
Name
Access
Rule
Data
Type
Values Description
16#00
D0 Set
INT
16#00
16#01
INT 16#00
16#02~16#752E
D2~D29998 Set
INT 16#00
D2~D29998 word register
16# Max
DMax Set
INT 16#00
The maximum number of the
instance attribute is determined
by the sepecifiation of the
8.12.4 M Register (Class ID: 16#353)
Service Code
Service Code Service Name
Support
Description
Class Attribute
Instance
Attribute
16#0E Get_Attribute_Single X V
Read one attribute
16#10 Set_Attribute_Single X V
Write one attribute
16#32 Read_Parameter X V Read Parameter
16#33 Write_Parameter X V Write Parameter
Class
Class ID:16#353
Instance
16#01:Instance Attribute, Bit Register
When Instance = 1, the Class Attributes are listed below.
Instance Attribute
Name
Access
Rule
Data
Type
Values Description
16#00
M0 Set BOOL 16#00
16#01
16#02~16#1FFE
M2~M8190 Set BOOL 16#00 M2~M8190 word register
16# Max
MMax Set BOOL 16#00
The maximum number of the
instance attribute is determined
by the sepecifiation of the
connected AH series PLC.
8.12.5 S Register (Class ID: 16#354)
Service Code
Service Code Service Name
Support
Description
Class Attribute
Instance
Attribute
16#0E Get_Attribute_Single X V
Read one attribute
16#10 Set_Attribute_Single X V
Write one attribute
16#32 Read_Parameter X V Read Parameter
16#33 Write_Parameter X V Write Parameter