Chapter 11 DeviceNet Master Scanner Module AS01DNET-A
11-7
1
1
11.3 DeviceNet Network Communication
11.3.1 Relationship between Transmission Distance and Baud Rate
The transmission distance of a DeivceNet network is determined by the baud rate. The following table shows the
corresponding maximum communication distance at different baud rates.
Baud rate (bits/s)
10K 20K 50K 125K 250K 500K 800K 1M
Max. transmission
distance (M)
5000 2500 1000 500 250 100 50 25
11.3.2 DeivceNet Network Topology Structure