Chapter 12 Descriptions of Parameter SettingsC2000 Plus
12.1-02-2
02-05
Multi-Function Input Command 5 (MI5)
02-06
Multi-Function Input Command 6 (MI6)
02-07
Multi-Function Input Command 7 (MI7)
02-08
Multi-Function Input Command 8 (MI8)
02-26
Input Terminal of I/O Extension Card (MI10)
02-27
Input Terminal of I/O Extension Card (MI11)
02-28
Input Terminal of I/O Extension Card (MI12)
02-29
Input Terminal of I/O Extension Card (MI13)
02-30
Input Terminal of I/O Extension Card (MI14)
02-31
Input Terminal of I/O Extension Card (MI15)
Default: 0
Settings
0: No function
1: Multi-step speed command 1 / multi-step position command 1
2: Multi-step speed command 2 / multi-step position command 2
3: Multi-step speed command 3 / multi-step position command 3
4: Multi-step speed command 4 / multi-step position command 4
5: Reset
6: JOG operation (by external control or KPC-CC01)
7: Acceleration / deceleration speed inhibit
8: 1
st
and 2
nd
acceleration / deceleration time selection
9: 3
rd
and 4
th
acceleration / deceleration time selection
10: External Fault (EF) input (Pr.07-20)
11: Base Block (B.B) input from external
12: Output voltage stops
13: Cancel the setting of auto-acceleration / auto-deceleration time
14: Switch between motor 1 and motor 2
15: Rotating speed command from AVI
16: Rotating speed command from ACI
17: Rotating speed command from AUI
18: Forced to stop (Pr.07-20)
19: Frequency up command
20: Frequency down command
21: PID function disabled
22: Clear the counter
23: Input the counter value (MI6)
24: FWD JOG command
25: REV JOG command
26: TQC / FOC mode selection
27: ASR1 / ASR2 selection
28: Emergency stop (EF1)
29: Signal confirmation for Y-connection
30: Signal confirmation for Δ-connection
31: High torque bias (Pr.11-30)