Chapter 7 Optional AccessoriesME300
7-50
7-13 Digital Keypad–KPC-CC01, KPC-CE01
7-13-1 Keypad Panel introduction
The default communication protocol for ME300 is ASCII 9600, 7, N, 2, whereas the default communication
protocol for KPC-CC01 is RTU 19200, 8, N, 2. So you must set the ME300 communication parameters as
follows to connect it to KPC-CC01.
Pr.09-00 Communication Address: Settings = 1
Pr.09-01 COM1 Transmission Speed (Baud rate): Settings = 19.2 Kbps
Pr.09-04 COM1 Communication Protocol: Settings = 13: 8N2 (RTU)
KPC-CC01 KPC-CE01
Communication Interface
RJ45 (socket), RS-485
interface
Installation Method
Installed from external. The front cover is waterproof.
Buy a MKC-KPPK model to do wall mounting or
embedded mounting. Its protection level is IP66.
The maximum RJ45 extension lead is 5 m (16 ft)
This keypad can only be used on Delta’s motor drive
C2000, CH2000, CP2000, MS300, MH300, and
ME300.
Descriptions of Keypad Functions
Key
Descriptions
Start Operation Key
1. It is only valid when the source of operation command is from the keypad.
2. It can operate the AC motor drive by the function setting and the RUN LED will be ON.
3. It can be pressed repeatedly at stop process.
Stop Command Key. This key has the highest processing priority in any situation.
1. When it receives STOP command, regardless of whether the AC motor drive is in
operation or stop status, the AC motor drive executes the “STOP” command.
2. The RESET key can be used to reset the drive after a fault occurs.
3. If you cannot reset after the error:
a. The condition which triggers the fault is not cleared. After you clear the condition, you
can then reset the fault.
b. The drive is in fault status when powered on. After you clear the condition, restart and
then you can reset the fault.
Operation Direction Key
1. This key only controls the operation direction, NOT the drive activation. FWD: forward,
REV: reverse.
2. Refer to “Descriptions of LED Functions” for more details.
ENTER Key
Press ENTER to go to the next menu level. If you are at the last level, press ENTER to execute
the command.
ESC Key
ESC key function is to leave the current menu and return to the previous menu. It also functions
as a return key or cancel key in a sub-menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD5A5ME43ANNAA and is the answer not in the manual?

Delta VFD5A5ME43ANNAA Specifications

General IconGeneral
BrandDelta
ModelVFD5A5ME43ANNAA
CategoryDC Drives
LanguageEnglish

Related product manuals