Chapter 3
To Quick Exit
LCD Display
1. When the system is already set and the Set light is lit, press and hold the Quick
Exit key for 2 seconds
OR
press [*][0].
Quick Exit in
Progress
2. Exit the premises before the exit delay timer expires. After exiting, the delay timer will be
canceled.
3.7 Setting the System with a 2-Way Wireless Key
If configured, the PowerSeries Neo system can be set using the following wireless keys:
l PG4929/PG8929/PG9929
l PG4939/PG8939/PG9939
To Set the System with a 2-way wireless key
l Press the desired Setting mode button anytime the system Ready indicator is on.
3.8 Bypassing Zones
WARNING!If a zone is not operating properly contact a service person immediately.
Bypassing zones intentionally unprotects specified zones the next time your system is set. Depending on the type of keypad,
bypassed zones will be identified differently. Using an HS2LCD series keypad, bypassed zones are indicated on the LCD screen as
shown in the following table. If using an LED or ICN series keypad, the will light and the bypassed zones #s will be shown.
LCD Display Indication Description
Zone Label <>
none Zone is ready for setting.
Zone Label <>
O
O Zone is currently open. You may be unable to set the system.
Zone Label <>
B
B Zone is bypassed.
LCD Keypad Zone Indications
Bypassed zones:
l Must be configured before setting the system.
l Can be done using a keypad or SMS.
l Allow for access to protected areas when the system is set.
l Allow you to set the system if a zone is temporarily out of service.
l Reduce the level of security.
l Will not sound an alarm.
l Are automatically cancelled each time the system is unset.
l Can be programmed together within bypass groups. For more information see “Bypass Groups”.
3.8.1 Additional Bypass Features
RecallLastBypass Recalls all zones that were bypassed the last time the bypass zone feature was used.
BypassAllOpen
Zones
Allows the user to quickly bypass all open zones with a single command.
ClearBypass Instantly clears all bypass conditions from the zones assigned to the partition.
Programminga
BypassGroup
Use when you consistently bypass the same zones. This feature allows you to store in memory one
group of bypassed zones per partition.
ActivatingaBypass
Group
Loads a stored bypass group from memory.
Note:Ensure that no zones are unintentionally bypassed when setting your system.
Note:24-hour zones can only be unbypassed manually.
Note:For security reasons, your installer has programmed the system to prevent you from bypassing certain zones (e.g., smoke
detectors). For more information on fire zones see “Fire and CO Zone Types”.
To Bypass Individual Zones LCD Display
- 10 -