Chapter 3
3. Press [0][0][0]
OR
Scroll to Clear Bypasses using the keys and press [*]. All Bypassed zones
will now be open.
Press (*) for <>
Clear Bypasses
then
Bypass Cleared
Zones Unbypassed
4. To exit bypassing mode press [*].

3.9 Bypass Groups
Program frequently bypassed zones into the system as a bypass group. Using bypass groups avoids individually bypassing each zone.
One bypass group can be programmed per partition.
Note:This feature is not to be used in UL listed installations.

To Program a Bypass Group LCD Display
1. Press [*] to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press [*] or [1]. If required enter your [access code].
Scroll to <>
Bypass Zones
3. Enter the [3 digit zone #] of all zones you want bypassed
OR
Scroll to and press [*] to indicate all zones you want bypassed.
Upstrs H Wdw <>
B
4. Press [9][9][5] to program the bypass group with the currently bypassed zones
OR
Scroll to Bypass Options using the keys and press [*]. Scroll to Prg Bypass
Group and press [*].
Press (*) for <>
Prg Bypass Group
5. The Bypass Group is now programmed. The keypad will beep three times.
Bypass Group
Programmed
6. To exit bypassing mode and return to the Ready state, press .
System is
Ready to Arm
To Load a Bypass Group LCD Display
1. Press [*] to enter the function menu.
Press (*) for <>
Zone Bypass
2. Press [*] or [1]. If required enter your [access code].
Scroll to <>
Bypass Zones
 
3. Press or [9][9][1]. If required enter your [access code].
OR
Scroll to Bypass Options using the keys and press [*]. Scroll to Bypass
Group and press [*].
Press (*) for <>
Bypass Group
4. The group of zones are now bypassed. The following message briefly displays.
Bypass Group
Zones Bypassed
5. To exit bypassing mode and return to the Ready state, press [*].

6. If using an LED or ICN series keypad, the will light and the bypassed zones #s will
be shown. If the system is ready to set the Ready indicator will be lit. When setting
the system the following message briefly displays.
* Warning *
Bypass Active
3.10 Setting Errors and Exit Faults
The PowerSeries Neo audibly notifies you of any errors when you are attempting to set the system or exit the premises.
3.10.1 Setting Errors
An error tone (long beep) sounds if the system is unable to set. Setting errors occur if:
l The system is not ready to set (i.e., sensors are open).
l An incorrect user code is entered.
l A trouble is present and has not been viewed by the user. This operation must be enabled by the installer.
- 12 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo Power HS2016 and is the answer not in the manual?

DSC Neo Power HS2016 Specifications

General IconGeneral
BrandDSC
ModelNeo Power HS2016
CategorySecurity System
LanguageEnglish

Related product manuals