- 219 -
Appendix 7: Specifications
Zone Configuration
l 16, 32, 64, or 128 wireless zones supported and up to 8 hardwired zones available on the controller
l 40 zone types and 14 programmable zone attributes
l Zone configurations available: normally closed, single EOL and DEOL supervised
l Hardwired zone expansion (fully supervised) available using the model HSM2108 (eight zone expander module)
l Wireless zone expansion (fully supervised) available using the HSM2Host 2-way wireless integration module (oper-
ating at 915MHz (North America), 433MHz (Europe) and 868MHz (international)
Access Codes
l Up to 97 access codes: 94 (level 2-EN), one system master code (level 3-EN), one installer code (level 3-EN), and
one maintenance code
l Programmable attributes for each user code (see "Access Code Attributes" on page 49)
l When using 6-digit access codes, the minimum number of variations of access codes are 10526 for
HS2128/HS2064,13888 for HS2032 and 20833 for HS2016-4
Warning Device Output
l Integral sounder capable of 85 dB @ 3m, self-powered type Z
l 2 remote, wireless indoor/outdoor warning devices supported: models PGX901 (indoor), PGX911 (outdoor) (X=4, 8,
or 9)
l Programmable as steady, pulsed or temporal three (as per ISO8201) and temporal four (CO alarm) output
l Warning device sounds alarms in the following priority: fire, CO, burg
Memory
l CMOS EEPROM memory
l Retains programming and system status on AC or battery failure for 20 years min. (not verified by UL)
Power Supply - North America
Transformer: DSC PTD1640U, PTD1640
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
l Input ratings: 220V-240Vac, 50/60Hz, 200mA
l Transformer required, mounted in the same enclosure, permanently connected
l Transformer secondary ratings: 16.5Vac, 40VA min.
Note: For installations using the transformer mounted inside the cabinet, replace fuse only with the same type (20mm) rated
250V/315mA.
Regulated power supply:
l 1.7A regulated, supervised and integral to the control unit
l Type A as per EN50131-6 Standard
l 700mA auxiliary supply, 12V DC
l Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l Reverse battery detection/protection
l Supervision for AC power and low battery
l Normal and high current battery charge options
l Supervised battery charging circuit
Current draw (panel):
l 85mA (nominal) 2A(Max)
Bell Output:
l 12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
l Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l Bell short detection (software + hardware)
Aux+:
l Voltage range = 9.6V - 13.8V DC
l Current = 700mA (shared with Corbus R(ed))
l Output ripple voltage: 270mVp-p max.