2.4 Radiation protection
Comply with all applicable X-ray protection
rules and take all required X-ray protection
measures.
Use the prescribed X-ray protection equip-
ment.
In order to reduce the level of X-ray exposure,
we recommend the use of bismuth, lead
shielding or protective aprons, especially for
children and teenagers.
The persons operating the equipment must
keep away from the X-ray unit while the expo-
sure is being taken. The minimum distance
required by law must be maintained (e.g. Ger-
many 1.5 m, Austria 2.0 m).
Children and pregnant women must consult a
doctor before having an X-ray taken.
Nobody else must be in the radiation room
without X-ray protection measures apart from
the patient. In exceptional circumstances
another person may be present to provide
assistance, but this must not be a member of
the surgery staff. When the exposure is being
taken, make sure that you maintain visual con-
tact with the patient and the unit and keep talk-
ing to the patient.
The radiation room must be lockable to prevent
entry by unauthorised persons.
If a fault occurs, cancel the exposure immedi-
ately by letting go of the trigger button.
2.5 Specialist personnel
Operation
Unit operating personnel must ensure safe and
correct handling based on their training and
knowledge.
Instruct or have every user instructed in han-
dling the unit.
Installation and repairs
Installation, readjustments, alterations,
upgrades and repairs must be carried out by
Dürr Dental or by qualified personnel specifi-
cally approved and authorized by Dürr Dental.
2.6 Electrical safety
Comply with all the relevant electrical safety
regulations when working on the unit.
Never touch the patient and unshielded plug
connections on the device at the same time.
Replace any damaged cables or plugs immedi-
ately.
2.7 Only use original parts
Only use accessories and optional items that
have been recommended or specifically
approved by Dürr Dental.
Only use only original wear parts and replace-
ment parts.
2.8 Transport
The original packaging provides optimum protec-
tion for the unit during transport.
If required, original packaging for the unit can be
ordered from Dürr Dental.
Dürr Dental will not accept any responsi-
bility or liability for damage occurring dur-
ing transport due to the use of incorrect
packaging, even where the unit is still
under guarantee.
Only transport the unit in its original packaging.
Keep the packing materials out of the reach of
children.
2.9 Disposal
Unit
The unit must be disposed of properly.
Within the European Union, the unit must
be disposed of in accordance with EU
Directive 2012/19/EU (WEEE).
If you have any questions about the correct
disposal of parts, please contact your dental
trade supplier.
X-ray emitter
The X-ray unit contains a tube that is potentially
capable of imploding, lead cladding and mineral
oil.
Important information
2202100028L02 2007V019 5
EN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Durr Dental VistaIntra and is the answer not in the manual?

Durr Dental VistaIntra Specifications

General IconGeneral
BrandDurr Dental
ModelVistaIntra
CategoryMedical Equipment
LanguageEnglish

Related product manuals