Eaton 9130 700/3000 VA UPS User’s Guide 164201718—Rev 7 www.eaton.com/powerquality 3
Chapter 2 Safety Warnings
IMPORTANT SAFETY INSTRUCTIONS — SAVE THESE INSTRUCTIONS
This manual contains important instructions that you should follow during installation and
maintenance of the UPS and batteries. Please read all instructions before operating the equipment
and save this manual for future reference.
DANGER
This UPS contains LETHAL VOLTAGES. All repairs and service should be performed by
AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the
UPS.
WARNING
l
This UPS contains its own energy source (batteries). The UPS output may carry live voltage
even when the UPS is not connected to an AC supply.
l
To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity
controlled, indoor environment, free of conductive contaminants. Ambient temperature must
not exceed 40C (104F). Do not operate near water or excessive humidity (90% maximum).
l
To reduce the risk of fire, connect only to a circuit provided with branch circuit overcurrent
protection in accordance with the National Electrical Code (NEC), ANSI/NFPA 70.
l
Output overcurrent protection and disconnect switch must be provided by others.
l
To comply with international standards and wiring regulations, the sum of the leakage current of
the UPS and the total equipment connected to the output of this UPS must not have an earth
leakage current greater than 3.5
milliamperes.
l
If installing an optional rackmount Extended Battery Module (EBM), install the EBM(s) directly
below the UPS so that all wiring between the cabinets is installed behind the front covers and is
inaccessible to users. The maximum number of EBM(s) per UPS is four.
l
If the UPS requires any type of transportation, verify that the UPS is unplugged and turned off
and then disconnect the UPS internal battery connector (see
Figure 24 on page 46 for
rackmount models or Figure 26 on page 48 for tower models).
CAUTION
l
Batteries can present a risk of electrical shock or burn from high short-circuit current. Observe
proper precautions. Servicing should be performed by qualified service personnel
knowledgeable of batteries and required precautions. Keep unauthorized personnel away from
batteries.
l
Proper disposal of batteries is required. Refer to your local codes for disposal requirements.
l
Never dispose of batteries in a fire. Batteries may explode when exposed to flame.