Maintenance
Maintenance details
Ignition electrode
The ignition electrode is a consumption
part and must be checked annually.
The electrode must be renewed, if
damages or any wear and tear is
detected. Furthermore, the value of
the ionization current can be detected
through measurements. Under full load
operations, the minimum ionization
current must amount to 4µ A. If the
inspection glass should be damaged,
then the entire ignition electrode must
be exchanged.
Exchange of the ignition electrode
- Remove all plug connections from
the ignition electrode.
- Push the clips at both sides of the
electrode outward and pull out the
electrode. Examine the seal of the
ignition electrode and replace it in
case of defect.
Assembly is carried out in the reverse
order.