126 Maintenance
4.3 Spare parts and mounting
Refer to the Spare Parts manuals, technical bulletins, e-learning videos and training
courses provided by the Manufacturer.
4.4 Routine maintenance (cleaning, replace-
ments, checks)
During normal operation, we recommend performing routine checks in order to verify
that there are no critical operating conditions.
We recommend following the following schedule:
Frequency Intervention
15 days Filter cleaning (very dusty environment).
30 days Filter cleaning (not very dusty environment).
Check the direct and reflected output power.
Check telemetry operates properly, if applicable.
Check the RF modules operate properly.
Check the power supplies operate properly
6 months Check the fans work properly.
Check the operating temperatures of the equipment.
Check the electric consumption.
12 months Check the output RF connector closes properly.
Check the condition of the electric connections.
Check that the fan blades and the air grille are clean (dusty
environment). To be performed when the equipment is in
Stand-by mode.
Filter washing (dusty environment).
24 months Filter washing (not very dusty environment).
Filter replacement (dusty environment).