63Use instructions
3.1.1.18 Clock pwr target
As well as the standard power adjustment, it can also be set according to time slots in
order to save energy.
For the power delivered to be set according to individual time slots, the option which
makes it fixed for 24 hours must be deactivated.
To do so set “For All 24 Hours: FALSE”.
The list of the time slots into which the whole day is divided is then displayed. Each
time slot lasts one hour.
Go to the time slot for which you want to change the power, press the encoder to make
it editable, set the new target power by turning the encoder, then press again to con-
firm.
3.1.1.19 Com. ID LC/RT disp. mode
Setting the addresses and activating the display so that the menus are also visible in
REMOTE mode.
3.1.1.20 Temperature unit
Setting the temperature unit of measurement.