FB2100/FB2200 Flow Computer CPU Enclosure & Electronics Field Replacement Guide
D301803X012
November 2020
23
Replacing the CPU Enclosure (Bottom)
1.
Slide the connectivity board into the bottom of the new CPU enclosure. The Ethernet port must
fit into its matching opening on the side of the enclosure.
2.
If present, replace the optional 6-channel expansion I/O board. See Replacing the 6-Channel
Expansion I/O Board on page 18.
3.
Replace the CPU board. See Replacing the CPU Board on page 16.
4.
Reattach the adapter board. See Replacing the Adapter Board on page 14.
5.
Reattach the CPU enclosure cover. See Replacing the CPU Enclosure Cover (Top) on page 11.
6.
Re-attach the CPU enclosure to the battery compartment. See Re-attaching the CPU Enclosure to
the Battery Compartment on page 9.
7.
Re-connect the cable between the CPU enclosure and the sensor module.
8.
Reattach the HMI module. See Replacing the HMI Module on page 6.

Other manuals for Emerson ControlWave Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson ControlWave Series and is the answer not in the manual?

Emerson ControlWave Series Specifications

General IconGeneral
BrandEmerson
ModelControlWave Series
CategoryDesktop
LanguageEnglish

Related product manuals