Configuring Switches in a Stack
3-14 Hardware Installation
Recommended Procedures for New and Existing Stacks
Installing a New Stackable System of Up to Eight Switches
Usethefollowingproceduretoinstallanewstackofuptoeightswitchesoutofthebox.
Beforeapplyingpower,makeallphysicalconnectionswiththestackcablesasdescribed
inConnectingHighSpeedSta c kingCablesonpage 311.
1. Onceallofthestackcableshavebeenconnected,individually
poweroneachswitch
fromtoptobottom(connectingpowertoaswitchisdescribedinConnectingACand
RPSPoweronpage 315).
Iftheswitchesarepoweredonalmostsimultaneously,thesystemwillautomatically
selectthefirstonethatpowersupastheMasterswitchandthe
othersasMember
switches.TheswitchesareassignedunitIDsintheorderthattheybecomefully
operational.
YoucancontroltheunitIDassignmentaccordingtothephysicalpositioninastack.
Whenyoupowerupeachswitchandallowittobecomefullyoperationalbefore
applyingpowertothe
nextswitch,thefirstonebecomestheManagerandallthenext
switcheswilljointhatstack(regardlessofPriority,FirmwareRevision,orMAC
Address).TheswitchesareassignedunitIDsintheorderthatyoupoweroneach
switch.
2. (Optional)Ifdesired,changethemanagementswitchusingthesetswitch
movemanagementcommandasdescribedintheSecureStackC2ConfigurationGuide.
3. Oncethedesiredmasterswitchhasbeenselected,resetthesystemusingthereset
commandasdescribedintheSecureStackC2ConfigurationGuide.
Adding a New Switch to an Existing Stack
Usethefollowingproceduretoinstallanewswitchtoanexistingstackconfiguration.
Thisprocedureassumesthatthenewswitchbeingaddedhasacleanconfigurationfrom
manufacturingandisrunningthesamefirmwareimageversionasotherswitchesinthe
stack.
1. Ensurethatpowerisoffonthenew
switchbeinginstalled.
Important
The following procedures assume that all switches have a clean configuration from manufacturing.
When adding a new switch to an already running stack, it is also assumed that the new switch is
using the same firmware image version as other switches in the stack.
Note: Once switch IDs are assigned, they are persistent and will be retained during a
power cycle to any or all of the switches.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G124-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G124-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G124-24
CategorySwitch
LanguageEnglish

Related product manuals