Page #37 background imageLoading...
Page #37 background image
S0740 800 179/E071123/P64
-- 3 7 --
ct33f1
Code AC
unit
Remote
control
unit
Power
source
Welding
data
unit
Description
20 High inductance in the welding circuit x
*22 T ransmitter buffer overflow x x x
*23 Receiver buffer overflow x x x
*25 Lost contact with AC unit x
*26 Program operating fault x
*28 Stack overflow x x x
*40 Incompatible units x
Fault codes marked with an asterisk ( * ) are not displayed by the control panel. but they
are stored in the fault log. To get access to the fault log use the ESAT service tool. See
page 43.
Fault code description
This manual describes the fault codes for the power source and the AC unit. The fault
codes for the other units are described in the manuals for these units.
Note! The welding data unit is operated by the processor of the control board in the power
source. The fault codes for the welding data unit are described in the service manual for the
control panel.
Power source
Code Description, power source
1 EPROM check sum error -- program memory error
Check sum test of the program memory, which is run only when initiating the power source
after power--up. This fault does not disable any functions.
The program memory is damaged. This is a serious fault, that can have unforeseen effects.
Action: Restart the machine. If the fault persists, load new software via ESAT. If the fault still
persists, replace circuit board 20AP1, which carries the memory chip.
2 Microprocessor RAM error
The microprocessor is unable to read/write from/to a particular memory address in its
internal memory. This test is preformed only on initiation after power--up. This fault does not
disable any functions.
Action: Restart the machine. If the fault persists, replace circuit board 20AP1, which carries
the microprocessor chip.
3 Error in external RAM
Read/write test of the processor’s internal external RAM. This test is preformed only as part
of initiation after power--up. The microprocessor is unable to read/write from/to a particular
memory address in its external memory. This fault does not disable any functions.
Action: Restart the machine. If the fault persists, replace circuit board 20AP1, which carries
the microprocessor chip.

Table of Contents

Other manuals for ESAB Caddy Tig 2200i AC/DC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ESAB Caddy Tig 2200i AC/DC and is the answer not in the manual?

ESAB Caddy Tig 2200i AC/DC Specifications

General IconGeneral
AC Frequency20 - 250 Hz
Dimensions418 x 188 x 345 mm
Weight15 kg
Protection ClassIP23
Frequency50/60 Hz
Duty Cycle (TIG DC, 220A)25%
Duty Cycle (TIG AC, 220A)25%
Input Voltage230 V
Current Range (TIG AC/DC)220 A