S0740 800 179/E071123/P64
Rating plate with
supply connec-
tion data
-- 5 8 --
ct33i
INSTRUCTIONS
This chapter is an extract from the instruction manual for the Tig 2200i AC/DC.
SAFETY
CAUTION!
Read and understand the instruction manual before
installing or operating.
INSTALLATION
The installatio n must be execu ted by a p rofession al.
Lifting instructions
Install the carrying strap as illustrated
and lift the power source by the strap.
Location
Position the welding power source such that its cooling air inlets and outlets are not
obstructed.
Mains power supply
Check that the welding power source is connected to the
correct mains power supply voltage, and that it is
protected by the correct fu se size.
A protective earth connection must be made in
accordance with regulations.
Recommend ed fuse s izes and minimum cable area
TIG MMA
Mains voltage 230 V ¦10 %,1μ 230 V ¦10 %,1μ
Mains frequency 50 Hz 50 Hz
Mains cable area mm
2
3G2.5 3G2.5
Phase current IRMS 14 A 15.3 A
Fuse
anti--surge
type C MCB
16 A
16 A
16 A
16 A
Note! The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the welding power source in accordance with the relevant national regulations.