4. Trouble Shooting and Maintenance
4.1 Diagnostic screen
Diagnostic screen can be entered into any time by press the “i” key located
at the left bottom keyboard.
1. Ink : real time pressure of Ink. It is generally 300-350 under normal
startup mode. Temp: Temperature of ink in the ink system
2. Temp:Cabinet : Temperature inside the cabinet
Head: Temperature of print head of inkjet printer. It is generally 35 under
normal startup mode.
3. Phase Profile: Phase working status. It is generally 06~10 under normal
startup mode.
4. Levels: Ink Low: Ink level in the ink tank now is low
Solvent Low: Solvent level in the solvent tank now is low
5. Chamber:Low, High: Low, high level status in the viscosity chamber.
ON and OFF will alternate when the printer is running
6. VMS:Set: Setting value of ink viscosity during running. The value will
vary because of different ink and temperature. Now: Actual value of
the ink viscosity during running; normally, the actual value
approximates to the setting value of ink viscosity.
7. Mix:OK,Low, High——Low, medium and high ink level probe in the
mixing tank. ON means there is ink in the tank, OFF means no ink.!