Technical data
Special voltage
WARNING!
Danger due to insufficiently dimensioned electrical installations.
Serious damage to property possible.
▶
The mains lead and its fuse protection must be rated accordingly.
▶
The technical data shown on the rating plate applies.
MagicWave
2600/2600CEL
MW 2600 MW 2600CEL
Grid voltage 3x400 V 3x400 V
Mains voltage tolerance -20% / +15% -20% / +15%
Mains fuse, slow-blow 16 A 16 A
Apparent power at
40% ED
50% ED
60% ED
100% ED
-
11.1 kVA
10.6 kVA
8.1 kVA
15.7 kVA
-
10.4kVA
8.1 kVA
Cos phi1
150 A
260 A
0.99
0.99
0.99
0.99
Efficiency 86% 83%
Welding current range
DC
AC
3 - 260 A
5 - 260 A
3 - 260 A
5 - 260 A
Welding current at 10 min/40°C
40% ED
50% ED
60% ED
100% ED
-
260 A
240 A
185 A
260 A
-
180 A
145 A
Open circuit voltage 56 V DC 75 V DC
max. working voltage 40 V 48 V
Striking voltage (Up).
The arc ignition device is suitable for
manual operation.
9.5 kV 9.5 kV
Protection class IP 23 IP 23
Type of cooling AF AF
Insulation class F F
Dimensions l/w/h 625/290/480 mm
24.61/11.42/18.90 in.
625/290/480 mm
24.61/11.42/18.90 in.
Weight (without cooling unit) 33 kg
72.75 lb.
30 kg
66.14 lb.
Mark of conformity CE, CSA CE, CSA
Safety signs S S