Special 4-step:
Version 2-4
The variants of the special 4-step mode shown below enable the intermediate lowering
to the set lowering current by means of TIG torches with double-button function.
- Select 4-step mode
- Set the setup parameter SFS to "2, 3, 4 or 5" for the desired variant (section "Pro-
gram level preferences”)
I
t
I
H
GAS
I
S
t
down
I
E
G-L
I
H
I
E
t
up
t
down
t
up
G-H
Special 4-step mode: Version 2
I
t
I
H
GAS
I
S
t
down
I
E
G-L
I
H
I
E
t
up
t
down
t
up
G-H
Special 4-step mode: Version 3
I
t
I
H
GAS
I
S
G-L
I
H
I
E
t
up
t
down
t
up
G-L
Special 4-step mode: Version 4
38